Digital cardiovascular magnetic resonance (CMR) phantoms provide known anatomy and tissue properties for controlled imaging experiments, but existing frameworks offer limited population variability and limited control over how the surrounding torso adapts to a prescribed heart. We introduce TorsoGen, a geometry-conditioned generative framework for creating simulation-ready CMR torso phantoms. Given a biventricular foreground, TorsoGen generates anatomically coherent and variable thoracic label maps together with spatially varying effective proton density, T1 and T2 maps for differentiable bSSFP rendering. The framework therefore enables generative modelling of torso anatomy, tissue-property variability and image contrast while preserving explicit control of the cardiac geometry. TorsoGen was developed using 412 subjects and evaluated on 46 held-out cases from the SwissHeart cohort. Generated foregrounds preserved the prescribed anatomy, with Dice scores of 0.971 ± 0.003 for myocardium, 0.991 ± 0.001 for the left-ventricular blood pool and 0.992 ± 0.001 for the right-ventricular blood pool. Organ-volume biases were below 7% for major thoracic structures. Autoregressive conditioning with curriculum corruption improved volumetric coherence, whereas independent two-dimensional generation produced excessive through-plane variation. Synthetic-only nnU-Net training approached real-only performance, with Dice scores of 0.809 ± 0.055 and 0.835 ± 0.049, respectively, while mixed real-synthetic training achieved 0.832±0.053 using half the real training volumes. TorsoGen provides a controllable generative framework for producing anatomically variable CMR torso phantoms with known cardiac geometry and spatially varying effective MR properties.

I fantocci digitali per la risonanza magnetica cardiovascolare (CMR) forniscono anatomia e proprietà tissutali note, e permettono perciò esperimenti di imaging in condizioni controllate. I framework esistenti offrono tuttavia una variabilità di popolazione limitata e uno scarso controllo sul modo in cui il torso circostante si adatta a un cuore prescritto. In questo lavoro si introduce TorsoGen, un framework generativo condizionato sulla geometria per la costruzione di fantocci toracici CMR pronti per la simulazione. Dato un foreground biventricolare, TorsoGen genera mappe di etichette toraciche anatomicamente coerenti e variabili, insieme alle corrispondenti mappe spazialmente variabili di densità protonica effcace, T1 e T2, destinate al rendering bSSFP differenziabile. Il framework consente quindi la modellazione generativa dell'anatomia del torso, della variabilità delle proprietà tissutali e del contrasto dell'immagine, preservando al tempo stesso il controllo esplicito della geometria cardiaca. TorsoGen è stato sviluppato su 412 soggetti e valutato su 46 casi di test della coorte SwissHeart, tenuti separati dall'addestramento. I foreground generati hanno preservato l'anatomia prescritta, con indici di Dice pari a 0,971 ± 0,003 per il miocardio, 0,991 ± 0,001 per la camera ematica del ventricolo sinistro e 0,992 ± 0,001 per quella del ventricolo destro. Gli scostamenti medi dei volumi d'organo si sono mantenuti al di sotto del 7% per le principali strutture toraciche. Il condizionamento autoregressivo con corruzione a curriculum ha migliorato la coerenza volumetrica, mentre la generazione bidimensionale indipendente ha prodotto una variazione eccessiva lungo la direzione ortogonale al piano. L'addestramento di nnU-Net sui soli dati sintetici si è avvicinato a quello sui soli dati reali, con indici di Dice rispettivamente di 0,809 ± 0,055 e 0,835 ± 0,049, mentre l'addestramento misto reale-sintetico ha raggiunto 0,832 ± 0,053 impiegando la metà dei volumi reali. TorsoGen fornisce dunque un framework generativo controllabile per la produzione di fantocci toracici CMR anatomicamente variabili, a geometria cardiaca nota e con proprietà MR effcaci spazialmente variabili.

TorsoGen : geometry-conditioned generation of CMR torso phantoms for physics-based image synthesis

Di CIANO, PAOLO
2025/2026

Abstract

Digital cardiovascular magnetic resonance (CMR) phantoms provide known anatomy and tissue properties for controlled imaging experiments, but existing frameworks offer limited population variability and limited control over how the surrounding torso adapts to a prescribed heart. We introduce TorsoGen, a geometry-conditioned generative framework for creating simulation-ready CMR torso phantoms. Given a biventricular foreground, TorsoGen generates anatomically coherent and variable thoracic label maps together with spatially varying effective proton density, T1 and T2 maps for differentiable bSSFP rendering. The framework therefore enables generative modelling of torso anatomy, tissue-property variability and image contrast while preserving explicit control of the cardiac geometry. TorsoGen was developed using 412 subjects and evaluated on 46 held-out cases from the SwissHeart cohort. Generated foregrounds preserved the prescribed anatomy, with Dice scores of 0.971 ± 0.003 for myocardium, 0.991 ± 0.001 for the left-ventricular blood pool and 0.992 ± 0.001 for the right-ventricular blood pool. Organ-volume biases were below 7% for major thoracic structures. Autoregressive conditioning with curriculum corruption improved volumetric coherence, whereas independent two-dimensional generation produced excessive through-plane variation. Synthetic-only nnU-Net training approached real-only performance, with Dice scores of 0.809 ± 0.055 and 0.835 ± 0.049, respectively, while mixed real-synthetic training achieved 0.832±0.053 using half the real training volumes. TorsoGen provides a controllable generative framework for producing anatomically variable CMR torso phantoms with known cardiac geometry and spatially varying effective MR properties.
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-ott-2026
2025/2026
I fantocci digitali per la risonanza magnetica cardiovascolare (CMR) forniscono anatomia e proprietà tissutali note, e permettono perciò esperimenti di imaging in condizioni controllate. I framework esistenti offrono tuttavia una variabilità di popolazione limitata e uno scarso controllo sul modo in cui il torso circostante si adatta a un cuore prescritto. In questo lavoro si introduce TorsoGen, un framework generativo condizionato sulla geometria per la costruzione di fantocci toracici CMR pronti per la simulazione. Dato un foreground biventricolare, TorsoGen genera mappe di etichette toraciche anatomicamente coerenti e variabili, insieme alle corrispondenti mappe spazialmente variabili di densità protonica effcace, T1 e T2, destinate al rendering bSSFP differenziabile. Il framework consente quindi la modellazione generativa dell'anatomia del torso, della variabilità delle proprietà tissutali e del contrasto dell'immagine, preservando al tempo stesso il controllo esplicito della geometria cardiaca. TorsoGen è stato sviluppato su 412 soggetti e valutato su 46 casi di test della coorte SwissHeart, tenuti separati dall'addestramento. I foreground generati hanno preservato l'anatomia prescritta, con indici di Dice pari a 0,971 ± 0,003 per il miocardio, 0,991 ± 0,001 per la camera ematica del ventricolo sinistro e 0,992 ± 0,001 per quella del ventricolo destro. Gli scostamenti medi dei volumi d'organo si sono mantenuti al di sotto del 7% per le principali strutture toraciche. Il condizionamento autoregressivo con corruzione a curriculum ha migliorato la coerenza volumetrica, mentre la generazione bidimensionale indipendente ha prodotto una variazione eccessiva lungo la direzione ortogonale al piano. L'addestramento di nnU-Net sui soli dati sintetici si è avvicinato a quello sui soli dati reali, con indici di Dice rispettivamente di 0,809 ± 0,055 e 0,835 ± 0,049, mentre l'addestramento misto reale-sintetico ha raggiunto 0,832 ± 0,053 impiegando la metà dei volumi reali. TorsoGen fornisce dunque un framework generativo controllabile per la produzione di fantocci toracici CMR anatomicamente variabili, a geometria cardiaca nota e con proprietà MR effcaci spazialmente variabili.
File allegati
File Dimensione Formato  
2026_10_Di_Ciano_Tesi.pdf

solo utenti autorizzati a partire dal 23/09/2027

Descrizione: Testo della tesi
Dimensione 2.77 MB
Formato Adobe PDF
2.77 MB Adobe PDF   Visualizza/Apri
2026_10_Di_Ciano_Executive_Summary.pdf

solo utenti autorizzati a partire dal 29/09/2027

Descrizione: Testo dell'Executive Summary
Dimensione 1.2 MB
Formato Adobe PDF
1.2 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/266381