Stress is a coordinated autonomic response to perceived challenges and, when recurrent without adequate recovery, is associated with adverse cardiovascular and mental-health outcomes. Electrodermal activity (EDA) is a sensitive peripheral marker of sympathetic activation, but conventional palmar and finger recording sites are poorly suited to continuous everyday monitoring. Smart eyewear offers an unobtrusive alternative, although head-based EDA remains largely unexplored. This thesis investigates the feasibility of acquiring EDA from the head using a compact AC-driven bioimpedance front-end (MAX30011) integrated into an eyewear platform. The sensing chain was first validated against a Shimmer3 GSR+ reference at the fingers during a Stroop task. A pilot study then screened candidate head electrode configurations and stress protocols, leading to a contralateral nose--temple placement and a computerised arithmetic task. The selected setup was subsequently evaluated in a 15-participant multimodal study including head and palmar EDA, ECG, dual PPG, respiration, peripheral temperature, and motion. Head-EDA acquisition proved technically feasible but not yet reliable at cohort level. The system reproduced reference dynamics at the fingers and recovered tonic, and partially phasic, activity at the head in the pilot study, although in the final cohort none of the four head-EDA features remained significant after correction and responses were strongly participant-dependent. The findings point to electrode--skin contact quality and mechanical stability as important contributors to this variability. Heart rate and respiratory rate provided the most consistent complementary stress-related responses, with peripheral temperature as a secondary candidate. These results support a multimodal smart-eyewear approach and informed the design of a next-generation laboratory prototype with compliant, force-monitored temple contacts. The prototype is documented at CAD, schematic, and PCB-layout level and has not been fabricated.

Lo stress è una risposta coordinata del sistema nervoso autonomo a una sfida percepita e, se si ripete senza un adeguato recupero, è associato a conseguenze negative per la salute cardiovascolare e mentale. L’attività elettrodermica (EDA) è un indicatore periferico sensibile dell’attivazione simpatica, ma i siti di misura convenzionali, palmo e dita, sono poco adatti al monitoraggio continuo. Gli smart eyewear sono un’alternativa poco invasiva, anche se l’EDA misurata sulla testa è ancora poco studiata. Questa tesi valuta la fattibilità dell’acquisizione di EDA dalla testa con un front-end di bioimpedenza compatto ad eccitazione in corrente alternata (MAX30011) integrato in una piattaforma eyewear. La catena di acquisizione è stata validata sulle dita rispetto allo Shimmer3 GSR+ durante un test di Stroop. Uno studio pilota ha poi confrontato configurazioni elettrodiche e protocolli di stress, portando a una configurazione naso--tempia controlaterale e a un compito aritmetico computerizzato. Il setup è stato infine valutato in uno studio multimodale su 15 partecipanti con EDA da testa e palmo, ECG, doppio PPG, respirazione, temperatura periferica e movimento. L’EDA dalla testa è risultata tecnicamente acquisibile ma non ancora affidabile a livello di coorte. Il sistema ha riprodotto la dinamica del riferimento sulle dita e, nello studio pilota, ha recuperato alla testa componenti toniche e in parte fasiche; nello studio finale nessuna delle quattro caratteristiche dell’EDA dalla testa è rimasta significativa dopo la correzione e le risposte sono risultate molto variabili tra partecipanti. I risultati indicano la qualità del contatto elettrodo--cute e la stabilità meccanica come fattori importanti di questa variabilità. Frequenza cardiaca e frequenza respiratoria hanno dato le risposte complementari più coerenti, con la temperatura periferica come candidato secondario. Questi risultati supportano un approccio multimodale e hanno guidato il progetto di un prototipo di laboratorio di nuova generazione con contatti temporali cedevoli e monitorati in forza, documentato a livello di CAD, schema elettrico e layout PCB ma non ancora fabbricato.

Toward multimodal stress-sensing smart eyewear: feasibility of head EDA

Carazza, Anna
2025/2026

Abstract

Stress is a coordinated autonomic response to perceived challenges and, when recurrent without adequate recovery, is associated with adverse cardiovascular and mental-health outcomes. Electrodermal activity (EDA) is a sensitive peripheral marker of sympathetic activation, but conventional palmar and finger recording sites are poorly suited to continuous everyday monitoring. Smart eyewear offers an unobtrusive alternative, although head-based EDA remains largely unexplored. This thesis investigates the feasibility of acquiring EDA from the head using a compact AC-driven bioimpedance front-end (MAX30011) integrated into an eyewear platform. The sensing chain was first validated against a Shimmer3 GSR+ reference at the fingers during a Stroop task. A pilot study then screened candidate head electrode configurations and stress protocols, leading to a contralateral nose--temple placement and a computerised arithmetic task. The selected setup was subsequently evaluated in a 15-participant multimodal study including head and palmar EDA, ECG, dual PPG, respiration, peripheral temperature, and motion. Head-EDA acquisition proved technically feasible but not yet reliable at cohort level. The system reproduced reference dynamics at the fingers and recovered tonic, and partially phasic, activity at the head in the pilot study, although in the final cohort none of the four head-EDA features remained significant after correction and responses were strongly participant-dependent. The findings point to electrode--skin contact quality and mechanical stability as important contributors to this variability. Heart rate and respiratory rate provided the most consistent complementary stress-related responses, with peripheral temperature as a secondary candidate. These results support a multimodal smart-eyewear approach and informed the design of a next-generation laboratory prototype with compliant, force-monitored temple contacts. The prototype is documented at CAD, schematic, and PCB-layout level and has not been fabricated.
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-ott-2026
2025/2026
Lo stress è una risposta coordinata del sistema nervoso autonomo a una sfida percepita e, se si ripete senza un adeguato recupero, è associato a conseguenze negative per la salute cardiovascolare e mentale. L’attività elettrodermica (EDA) è un indicatore periferico sensibile dell’attivazione simpatica, ma i siti di misura convenzionali, palmo e dita, sono poco adatti al monitoraggio continuo. Gli smart eyewear sono un’alternativa poco invasiva, anche se l’EDA misurata sulla testa è ancora poco studiata. Questa tesi valuta la fattibilità dell’acquisizione di EDA dalla testa con un front-end di bioimpedenza compatto ad eccitazione in corrente alternata (MAX30011) integrato in una piattaforma eyewear. La catena di acquisizione è stata validata sulle dita rispetto allo Shimmer3 GSR+ durante un test di Stroop. Uno studio pilota ha poi confrontato configurazioni elettrodiche e protocolli di stress, portando a una configurazione naso--tempia controlaterale e a un compito aritmetico computerizzato. Il setup è stato infine valutato in uno studio multimodale su 15 partecipanti con EDA da testa e palmo, ECG, doppio PPG, respirazione, temperatura periferica e movimento. L’EDA dalla testa è risultata tecnicamente acquisibile ma non ancora affidabile a livello di coorte. Il sistema ha riprodotto la dinamica del riferimento sulle dita e, nello studio pilota, ha recuperato alla testa componenti toniche e in parte fasiche; nello studio finale nessuna delle quattro caratteristiche dell’EDA dalla testa è rimasta significativa dopo la correzione e le risposte sono risultate molto variabili tra partecipanti. I risultati indicano la qualità del contatto elettrodo--cute e la stabilità meccanica come fattori importanti di questa variabilità. Frequenza cardiaca e frequenza respiratoria hanno dato le risposte complementari più coerenti, con la temperatura periferica come candidato secondario. Questi risultati supportano un approccio multimodale e hanno guidato il progetto di un prototipo di laboratorio di nuova generazione con contatti temporali cedevoli e monitorati in forza, documentato a livello di CAD, schema elettrico e layout PCB ma non ancora fabbricato.
File allegati
File Dimensione Formato  
2026_10_Carazza_Tesi.pdf

non accessibile

Descrizione: Testo della tesi
Dimensione 140.48 MB
Formato Adobe PDF
140.48 MB Adobe PDF   Visualizza/Apri
2026_10_Carazza_ExecutiveSummary.pdf

non accessibile

Descrizione: Executive Summary
Dimensione 2.48 MB
Formato Adobe PDF
2.48 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/266500