Camera calibration is required in many computer vision applications, but wide-angle cameras remain challenging because of their strong radial distortion and large field of view. LightCalib is a multi-view calibration framework specifically designed for radially symmetric wide-angle cameras. It extends the original Viewing-angle Camera Representation (VaCR) calibration method from single-view intrinsic calibration to an arbitrary number of images acquired with the same camera, while also estimating orientation-related information for each view. LightCalib is structured to reflect the underlying problem. The representation separates the camera geometry shared across the input views from the orientation information specific to each view. A neural network processes the images to estimate a single VaCR and a gravity vector for each view. For VaCR estimation, the method organizes image features according to radial symmetry and then combines them across views. The resulting VaCR is then fitted to the analytical camera model to recover the final intrinsic parameters. Experiments show that increasing the number of processed views improves calibration accuracy, reducing the VaCR mean absolute error by approximately 48% from one to eight views. Compared with the original single-view VaCR framework, LightCalib achieves a 32.1% reduction in VaCR MAE. LightCalib also achieves competitive results for camera orientation estimation compared with related methods. This trend is also observed on out-of-domain data, although accuracy decreases. Overall, LightCalib relies on a compact representation that is independent of the specific camera model and requires neither visual overlap nor correspondences between images.
La calibrazione della camera è un requisito fondamentale in molte applicazioni di computer vision, ma, nel caso di camere grandangolari, rimane particolarmente complessa a causa della forte distorsione radiale e dell’ampio campo visivo. LightCalib è un metodo che sfrutta più immagini per calibrare camere grandangolari radialmente simmetriche. Viene quindi presentato come estensione del metodo originale di calibrazione degli intrinseci basato sulla Viewing-Angle Camera Representation (VaCR) alla calibrazione di un numero arbitrario di immagini acquisite con la stessa camera e alla stima delle informazioni riguardanti l’orientamento della camera per ogni vista. La rappresentazione adottata separa le informazioni sulla geometria della camera, condivise tra le immagini dello stesso gruppo, da quelle specifiche di ogni vista relative all’orientamento della camera. Una rete neurale elabora le immagini per stimare una singola VaCR e una direzione della gravità specifica per ciascuna vista. Per la stima della VaCR, le caratteristiche delle immagini, organizzate secondo la simmetria radiale, vengono combinate fra le diverse viste. La VaCR ottenuta viene poi adattata al modello analitico di camera selezionato per ricavare i parametri intrinseci finali tramite un ulteriore processo di ottimizzazione. Gli esperimenti mostrano che, aumentando il numero di viste processate, l’accuratezza della calibrazione migliora, con una riduzione di circa il 48% dell’errore assoluto medio (MAE) sulla VaCR passando da una a otto viste. Rispetto al framework VaCR originale single-view, LightCalib ottiene una riduzione del 32,1% della MAE sulla VaCR. LightCalib ottiene inoltre risultati competitivi nella stima dell’orientamento della camera rispetto ad altri metodi comparabili. Questo comportamento si osserva anche su dati al di fuori del dominio, sebbene con una riduzione dell’accuratezza. Complessivamente, LightCalib si basa su una rappresentazione compatta e indipendente dal modello specifico della camera e non richiede alcuna sovrapposizione visiva né corrispondenze tra le immagini.
LightCalib: multi-View Wide-Angle Camera Calibration via Compact Radial Representation
CARATTI, ELENA
2025/2026
Abstract
Camera calibration is required in many computer vision applications, but wide-angle cameras remain challenging because of their strong radial distortion and large field of view. LightCalib is a multi-view calibration framework specifically designed for radially symmetric wide-angle cameras. It extends the original Viewing-angle Camera Representation (VaCR) calibration method from single-view intrinsic calibration to an arbitrary number of images acquired with the same camera, while also estimating orientation-related information for each view. LightCalib is structured to reflect the underlying problem. The representation separates the camera geometry shared across the input views from the orientation information specific to each view. A neural network processes the images to estimate a single VaCR and a gravity vector for each view. For VaCR estimation, the method organizes image features according to radial symmetry and then combines them across views. The resulting VaCR is then fitted to the analytical camera model to recover the final intrinsic parameters. Experiments show that increasing the number of processed views improves calibration accuracy, reducing the VaCR mean absolute error by approximately 48% from one to eight views. Compared with the original single-view VaCR framework, LightCalib achieves a 32.1% reduction in VaCR MAE. LightCalib also achieves competitive results for camera orientation estimation compared with related methods. This trend is also observed on out-of-domain data, although accuracy decreases. Overall, LightCalib relies on a compact representation that is independent of the specific camera model and requires neither visual overlap nor correspondences between images.| File | Dimensione | Formato | |
|---|---|---|---|
|
2026_10_Caratti_Thesis.pdf
non accessibile
Descrizione: Thesis
Dimensione
30.7 MB
Formato
Adobe PDF
|
30.7 MB | Adobe PDF | Visualizza/Apri |
|
2026_10_Caratti_Executive_Summary.pdf
accessibile in internet solo dagli utenti autorizzati
Descrizione: Executive Summary
Dimensione
1.41 MB
Formato
Adobe PDF
|
1.41 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/266540