Self-expandable transcatheter pulmonary valves were recently intro- duced to extend percutaneous pulmonary valve implantation (PPVI) to patients with large, native or patched right ventricular outflow tracts (RVOTs). For this patient group, predicting the device post-deployment configuration and the sta- bility of its interaction with the RVOT wall from pre-procedural imaging is even more critical. Finite element (FE) simulations can support this prediction, but their output depends on the modeling of device-specific Nitinol stress-strain re- sponse, and patient-specific native tissue and patch mechanical properties. All of these are largely unknown. On this basis, this work developed a FE frame- work to simulate the deployment of the Harmony transcatheter pulmonary valve (Medtronic), and a systematic sensitivity analysis on the mechanical properties of the different materials. To this aim, a virtual twin of the device was reconstructed through reverse engineering from the 3D scan of the real valve, and its crimping and deployment were simulated in Abaqus/Explicit in patient-specific RVOT mod- els with a transannular patch, whose mechanical response was described as linear elastic with a secant elastic modulus at physiological working points derived from literature data obtained via equibiaxial tensile tests. Based on the computed post- deployment configuration, the cross-sectional geometry of each ring of the device stent, the stent–wall contact area and its angular distribution were quantified. The mechanical properties assigned to Nitinol were the dominant source of uncertainty: some combinations of values of constitutive parameters, albeit falling in the ranges published in the literature, led to failed or incomplete deployments. The remaining combinations yielded a contact area that varied by −12% to +13% vs. a baseline setting. RVOT wall mechanical properties had a smaller effect: tripling the stiff- ness of the RVOT wall reduced the total contact area by about 6%, with this effect confined to the two flares. As regards the patch, its presence mattered far more than its stiffness: across the patch materials the total contact area varied by only 2 mm2, whereas removing the patch increased it by 14%, mostly at the central rings of the prosthetic device, while the ring most covered by the patch was almost unaffected. Hence, the presence of the patch did not act only locally, on the por- tion of the stent lying against it, but altered the stent–wall contact along the whole device. The patch stiffness acted instead on the distribution of the contact area at the level of the patch, which was more homogeneous when the stiffness mismatch between RVOT wall and patch decreased. The comparison with the post-operative fluoroscopy of one patient yielded a mean relative error of 10.7% on the device diameter, practically independent of the stiffness assigned to the RVOT wall and to the patch. These preliminary findings should be extended to a cohort of PPVI recipients, possibly with a device-specific characterisation of the Nitinol frame.

Le valvole polmonari transcatetere autoespandibili sono state introdotte di recente per estendere l’impianto percutaneo di valvola polmonare (PPVI) ai pazienti con tratto di efflusso del ventricolo destro (RVOT) di grandi dimensioni, nativo o ricostruito con patch. In questi pazienti, prevedere a partire dall’imaging pre- procedurale la configurazione del dispositivo dopo il rilascio e la stabilità della sua interazione con la parete dell’RVOT è ancora più critico. Le simulazioni agli elementi finiti (FE) possono supportare questa previsione, ma il loro esito dipende dalla modellazione della risposta sforzo–deformazione del Nitinol specifico del dispositivo e dalle proprietà meccaniche, paziente-specifiche, del tessuto nativo e del patch, tutte in gran parte non note. Su queste basi, in questo lavoro è stato sviluppato un framework FE per simulare il rilascio della valvola polmonare transcatetere Harmony (Medtronic), insieme a un’analisi di sensibilità sistematica sulle proprietà meccaniche dei diversi materiali. A questo scopo, un gemello virtuale del dispositivo è stato ricostruito tramite reverse engineering dalla scansione 3D della valvola reale, e il suo crimpaggio e rilascio sono stati simulati in Abaqus/Explicit in modelli paziente-specifici di RVOT con patch transanulare, nei quali sia la parete nativa sia il patch sono stati descritti come lineari elastici, con un modulo elastico secante ricavato in corrispondenza di punti di lavoro fisiologici da dati di letteratura ottenuti tramite prove di trazione equibiassiale. Sulla configurazione post-rilascio calcolata sono state quantificate la geometria della sezione di ciascun anello dello stent, l’area di contatto stent–parete e la sua distribuzione angolare. Le proprietà meccaniche assegnate al Nitinol sono risultate la principale fonte di incertezza: alcune combinazioni dei parametri costitutivi, pur ricadendo negli intervalli pubblicati in letteratura, hanno portato a rilasci falliti o incompleti. Le restanti combinazioni hanno prodotto un’area di contatto totale variabile tra −12% e +13% rispetto a una configurazione di riferimento. Le proprietà meccaniche della parete dell’RVOT hanno avuto un effetto minore: triplicarne la rigidezza ha ridotto l’area di contatto totale di circa il 6%, con un effetto limitato ai due flare. Per quanto riguarda il patch, la sua presenza è risultata molto più rilevante della sua rigidezza: tra i diversi materiali l’area di contatto totale è variata di soli 2 mm2, mentre la rimozione del patch l’ha aumentata del 14%, soprattutto negli anelli centrali del dispositivo, lasciando quasi invariato l’anello più coperto dal patch. Il patch, quindi, non ha agito solo localmente, sulla porzione di stent appoggiata su di esso, ma ha modificato il contatto stent–parete lungo l’intero dispositivo. La rigidezza del patch ha agito invece sulla distribuzione dell’area di contatto in corrispondenza del patch, che è risultata più omogenea al diminuire della differenza di rigidezza tra parete dell’RVOT e patch. Il confronto con la fluoroscopia post-operatoria di un paziente ha restituito un errore relativo medio sul diametro del dispositivo del 10.7%, praticamente indipendente dalla rigidezza assegnata alla parete dell’RVOT e al patch. Questi risultati preliminari andranno estesi a una coorte di pazienti sottoposti a PPVI, eventualmente con una caratterizzazione del Nitinol specifica del dispositivo.

Deployment of the Harmony transcatheter pulmonary valve in native and patched right ventricular outflow tracts : a finite element study with uncertainty analysis on material properties

Scuriatti, Luca Carlo
2025/2026

Abstract

Self-expandable transcatheter pulmonary valves were recently intro- duced to extend percutaneous pulmonary valve implantation (PPVI) to patients with large, native or patched right ventricular outflow tracts (RVOTs). For this patient group, predicting the device post-deployment configuration and the sta- bility of its interaction with the RVOT wall from pre-procedural imaging is even more critical. Finite element (FE) simulations can support this prediction, but their output depends on the modeling of device-specific Nitinol stress-strain re- sponse, and patient-specific native tissue and patch mechanical properties. All of these are largely unknown. On this basis, this work developed a FE frame- work to simulate the deployment of the Harmony transcatheter pulmonary valve (Medtronic), and a systematic sensitivity analysis on the mechanical properties of the different materials. To this aim, a virtual twin of the device was reconstructed through reverse engineering from the 3D scan of the real valve, and its crimping and deployment were simulated in Abaqus/Explicit in patient-specific RVOT mod- els with a transannular patch, whose mechanical response was described as linear elastic with a secant elastic modulus at physiological working points derived from literature data obtained via equibiaxial tensile tests. Based on the computed post- deployment configuration, the cross-sectional geometry of each ring of the device stent, the stent–wall contact area and its angular distribution were quantified. The mechanical properties assigned to Nitinol were the dominant source of uncertainty: some combinations of values of constitutive parameters, albeit falling in the ranges published in the literature, led to failed or incomplete deployments. The remaining combinations yielded a contact area that varied by −12% to +13% vs. a baseline setting. RVOT wall mechanical properties had a smaller effect: tripling the stiff- ness of the RVOT wall reduced the total contact area by about 6%, with this effect confined to the two flares. As regards the patch, its presence mattered far more than its stiffness: across the patch materials the total contact area varied by only 2 mm2, whereas removing the patch increased it by 14%, mostly at the central rings of the prosthetic device, while the ring most covered by the patch was almost unaffected. Hence, the presence of the patch did not act only locally, on the por- tion of the stent lying against it, but altered the stent–wall contact along the whole device. The patch stiffness acted instead on the distribution of the contact area at the level of the patch, which was more homogeneous when the stiffness mismatch between RVOT wall and patch decreased. The comparison with the post-operative fluoroscopy of one patient yielded a mean relative error of 10.7% on the device diameter, practically independent of the stiffness assigned to the RVOT wall and to the patch. These preliminary findings should be extended to a cohort of PPVI recipients, possibly with a device-specific characterisation of the Nitinol frame.
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-ott-2026
2025/2026
Le valvole polmonari transcatetere autoespandibili sono state introdotte di recente per estendere l’impianto percutaneo di valvola polmonare (PPVI) ai pazienti con tratto di efflusso del ventricolo destro (RVOT) di grandi dimensioni, nativo o ricostruito con patch. In questi pazienti, prevedere a partire dall’imaging pre- procedurale la configurazione del dispositivo dopo il rilascio e la stabilità della sua interazione con la parete dell’RVOT è ancora più critico. Le simulazioni agli elementi finiti (FE) possono supportare questa previsione, ma il loro esito dipende dalla modellazione della risposta sforzo–deformazione del Nitinol specifico del dispositivo e dalle proprietà meccaniche, paziente-specifiche, del tessuto nativo e del patch, tutte in gran parte non note. Su queste basi, in questo lavoro è stato sviluppato un framework FE per simulare il rilascio della valvola polmonare transcatetere Harmony (Medtronic), insieme a un’analisi di sensibilità sistematica sulle proprietà meccaniche dei diversi materiali. A questo scopo, un gemello virtuale del dispositivo è stato ricostruito tramite reverse engineering dalla scansione 3D della valvola reale, e il suo crimpaggio e rilascio sono stati simulati in Abaqus/Explicit in modelli paziente-specifici di RVOT con patch transanulare, nei quali sia la parete nativa sia il patch sono stati descritti come lineari elastici, con un modulo elastico secante ricavato in corrispondenza di punti di lavoro fisiologici da dati di letteratura ottenuti tramite prove di trazione equibiassiale. Sulla configurazione post-rilascio calcolata sono state quantificate la geometria della sezione di ciascun anello dello stent, l’area di contatto stent–parete e la sua distribuzione angolare. Le proprietà meccaniche assegnate al Nitinol sono risultate la principale fonte di incertezza: alcune combinazioni dei parametri costitutivi, pur ricadendo negli intervalli pubblicati in letteratura, hanno portato a rilasci falliti o incompleti. Le restanti combinazioni hanno prodotto un’area di contatto totale variabile tra −12% e +13% rispetto a una configurazione di riferimento. Le proprietà meccaniche della parete dell’RVOT hanno avuto un effetto minore: triplicarne la rigidezza ha ridotto l’area di contatto totale di circa il 6%, con un effetto limitato ai due flare. Per quanto riguarda il patch, la sua presenza è risultata molto più rilevante della sua rigidezza: tra i diversi materiali l’area di contatto totale è variata di soli 2 mm2, mentre la rimozione del patch l’ha aumentata del 14%, soprattutto negli anelli centrali del dispositivo, lasciando quasi invariato l’anello più coperto dal patch. Il patch, quindi, non ha agito solo localmente, sulla porzione di stent appoggiata su di esso, ma ha modificato il contatto stent–parete lungo l’intero dispositivo. La rigidezza del patch ha agito invece sulla distribuzione dell’area di contatto in corrispondenza del patch, che è risultata più omogenea al diminuire della differenza di rigidezza tra parete dell’RVOT e patch. Il confronto con la fluoroscopia post-operatoria di un paziente ha restituito un errore relativo medio sul diametro del dispositivo del 10.7%, praticamente indipendente dalla rigidezza assegnata alla parete dell’RVOT e al patch. Questi risultati preliminari andranno estesi a una coorte di pazienti sottoposti a PPVI, eventualmente con una caratterizzazione del Nitinol specifica del dispositivo.
File allegati
File Dimensione Formato  
2026_10_Scuriatti.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: Tesi
Dimensione 17.84 MB
Formato Adobe PDF
17.84 MB Adobe PDF   Visualizza/Apri
2026_10_Scuriatti_Executive Summary.pdf

accessibile in internet per tutti

Descrizione: Executive Summary
Dimensione 2.7 MB
Formato Adobe PDF
2.7 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/266628