Piezoelectric transducers are the established technology for biomedical ultrasound imaging and therapy, but conventional designs can present challenges in miniaturization and bandwidth. Fiber-optic photoacoustic ultrasound transducers offer an alternative: a thin photoabsorbing coating at the fiber tip converts light pulses into ultrasound through rapid thermoelastic expansion. This approach can provide a broad acoustic spectrum supporting high spatial resolution, while the small dimensions of optical fibers facilitate integration into endoscopes, needles and catheters. Commonly used photoabsorbers include synthetic carbon-based materials and metallic nanostructures. Cuttlefish ink (CI), naturally rich in optically absorbing melanin, offers a bio-derived, potentially more sustainable and biocompatible alternative. Its demonstrated light-to-heat conversion in polydimethylsiloxane (PDMS) composites and biomedical photothermal formulations motivates its investigation for ultrasound generation. This thesis explored the fabrication of fiber-optic photoacoustic transducers using CI incorporated into a PDMS matrix. Different concentrations and dispersion procedures were tested, and the composites were dip-coated onto optical fibers with a 200 μm core and excited using a nanosecond pulsed laser. The fabricated transducers reached a maximum peak-to-peak pressure of 422.3 kPa and a maximum spectral bandwidth of 27.8 MHz, at a mean fluence of 12.2 mJ cm⁻². Higher pressures were associated with more homogeneous CI distributions and with increasing CI concentration from 5% to 10%. The latter was also associated with higher dominant frequencies and broader bandwidths. These results demonstrate the feasibility of CI as a bio-derived photoabsorber for photoacoustic transducers and identify dispersion and concentration as important parameters for coating morphology and acoustic response.
I trasduttori piezoelettrici sono la tecnologia consolidata per l’imaging e la terapia a ultrasuoni in ambito biomedico, ma le configurazioni convenzionali possono presentare difficoltà di miniaturizzazione e ampiezza di banda. I trasduttori di ultrasuoni fotoacustici basati su fibra ottica offrono un’alternativa: un sottile rivestimento fotoassorbente sulla punta della fibra converte impulsi luminosi in ultrasuoni mediante una rapida espansione termoelastica. Questo approccio può generare un ampio spettro acustico, favorendo un’elevata risoluzione spaziale, mentre le dimensioni ridotte delle fibre ne facilitano l’integrazione in endoscopi, aghi e cateteri. Fotoassorbenti comunemente usati sono materiali sintetici a base di carbonio o nanostrutture metalliche. L’inchiostro di seppia (CI), ricco di melanina in grado di assorbire la luce, offre un’alternativa di origine biologica, potenzialmente più sostenibile e biocompatibile. La sua capacità di convertire la luce in calore, dimostrata in compositi a base di polidimetilsilossano (PDMS) e in formulazioni fototermiche biomediche, ne motiva lo studio per la generazione di ultrasuoni. Questa tesi ha esplorato la fabbricazione di trasduttori fotoacustici basati su fibra ottica utilizzando CI incorporato in una matrice di PDMS. Sono state testate diverse concentrazioni e procedure di dispersione, e i compositi sono stati depositati per immersione su fibre ottiche con un nucleo di 200 μm ed eccitati mediante un laser pulsato a nanosecondi. I trasduttori fabbricati hanno raggiunto una pressione massima picco-picco di 422.3 kPa e un’ampiezza di banda spettrale massima di 27.8 MHz, a una fluenza media di 12.2 mJ cm⁻². Pressioni più elevate sono risultate associate sia a distribuzioni più omogenee del CI sia all’aumento della sua concentrazione dal 5% al 10%. Quest’ultimo è risultato inoltre associato a frequenze dominanti più elevate e bande più ampie. Questi risultati dimostrano la fattibilità dell’impiego del CI come fotoassorbente di origine biologica per trasduttori fotoacustici e identificano dispersione e concentrazione come parametri importanti per la morfologia del rivestimento e la risposta acustica.
Fabrication and characterization of a fiber-optic photoacoustic ultrasound transducer with a bio-derived photoabsorber
Caramanna, Alberto
2025/2026
Abstract
Piezoelectric transducers are the established technology for biomedical ultrasound imaging and therapy, but conventional designs can present challenges in miniaturization and bandwidth. Fiber-optic photoacoustic ultrasound transducers offer an alternative: a thin photoabsorbing coating at the fiber tip converts light pulses into ultrasound through rapid thermoelastic expansion. This approach can provide a broad acoustic spectrum supporting high spatial resolution, while the small dimensions of optical fibers facilitate integration into endoscopes, needles and catheters. Commonly used photoabsorbers include synthetic carbon-based materials and metallic nanostructures. Cuttlefish ink (CI), naturally rich in optically absorbing melanin, offers a bio-derived, potentially more sustainable and biocompatible alternative. Its demonstrated light-to-heat conversion in polydimethylsiloxane (PDMS) composites and biomedical photothermal formulations motivates its investigation for ultrasound generation. This thesis explored the fabrication of fiber-optic photoacoustic transducers using CI incorporated into a PDMS matrix. Different concentrations and dispersion procedures were tested, and the composites were dip-coated onto optical fibers with a 200 μm core and excited using a nanosecond pulsed laser. The fabricated transducers reached a maximum peak-to-peak pressure of 422.3 kPa and a maximum spectral bandwidth of 27.8 MHz, at a mean fluence of 12.2 mJ cm⁻². Higher pressures were associated with more homogeneous CI distributions and with increasing CI concentration from 5% to 10%. The latter was also associated with higher dominant frequencies and broader bandwidths. These results demonstrate the feasibility of CI as a bio-derived photoabsorber for photoacoustic transducers and identify dispersion and concentration as important parameters for coating morphology and acoustic response.| File | Dimensione | Formato | |
|---|---|---|---|
|
2026_10_Caramanna_Executive Summary.pdf
accessibile in internet per tutti a partire dal 29/09/2027
Descrizione: Executive Summary
Dimensione
3.51 MB
Formato
Adobe PDF
|
3.51 MB | Adobe PDF | Visualizza/Apri |
|
2026_10_Caramanna_Tesi.pdf
accessibile in internet per tutti a partire dal 29/09/2027
Descrizione: Thesis
Dimensione
13.46 MB
Formato
Adobe PDF
|
13.46 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/266796