Thrombosis in blood-contacting cardiovascular devices is governed by interactions among artificial surfaces, altered hemodynamics, and platelet-mediated mechanisms. This study investigated platelet deposition and thrombus formation on medical-grade BioSpan S polyurethane under physiological and supraphysiological shear, focusing on selective inhibition of vWF-GPIbα-mediated platelet capture and GPVI-dependent signaling. Reconstituted blood from six healthy donors was tested under paired untreated control, caplacizumab-treated, and glenzocimab-treated conditions at 1,000 and 10,000 s⁻¹ during 15-minute microfluidic perfusions. Time-resolved fluorescence intensity (FI), surface area coverage (%SAC), and mean thrombus area (MTA) were examined through kinetic profiles, 15-minute endpoints, integrated responses, and image sequences. Each treatment was analyzed separately against its paired untreated control. Separate exploratory fluorescence-background control experiments were performed. These experiments showed that FI contained time-dependent non-platelet- associated contributions, confirming the need to interpret FI, %SAC, MTA, and the images together. Validation of automated image processing against manual processing showed close agreement for %SAC, but less precise agreement for MTA at larger values. Untreated blood produced platelet deposition at both shear rates. At 10,000 s⁻¹, aggregates developed rapidly but underwent repeated growth, loss, regrowth, and embolization. Caplacizumab produced no consistent inhibition at 1,000 s⁻¹, whereas at 10,000 s⁻¹ it maintained %SAC and MTA near their initial values and significantly reduced endpoint %SAC and integrated %SAC and MTA. Glenzocimab did not significantly alter endpoint or integrated measurements at either shear rate. Several high-shear glenzocimab recordings showed repeated fluctuations and slow downstream aggregate displacement without remaining fixed at one surface location, compatible with altered consolidation or persistence. Because embolization also occurred in untreated controls and was not quantified, a glenzocimab-specific increase in instability could not be established. Side-view imaging in separate collagen-coated PDMS–glass channels was qualitatively feasible, but projection and signal overlap prevented direct thrombus-height quantification. Overall, the findings support a critical role for vWF-GPIbα in high-shear platelet capture and are consistent with a possible contribution of GPVI-dependent processes to post-recruitment aggregate consolidation and persistence.

La trombosi nei dispositivi cardiovascolari a contatto con il sangue deriva dall’interazione tra superfici artificiali, alterazioni emodinamiche e meccanismi piastrinici. Il presente studio ha analizzato la deposizione piastrinica e la formazione di trombi su poliuretano medicale BioSpan S in condizioni di shear fisiologico e sovrafisiologico, concentrandosi sull’inibizione della cattura piastrinica mediata da vWF-GPIbα e della segnalazione GPVI-dipendente. Sangue ricostituito di sei donatori sani è stato testato in condizioni di controllo non trattato, caplacizumab e glenzocimab a 1.000 e 10.000 s⁻¹ durante perfusioni microfluidiche di 15 minuti. Intensità di fluorescenza (FI), percentuale di area superficiale coperta (%SAC) e area media dei trombi (MTA) sono state analizzate mediante profili cinetici, valori finali, misure integrate e immagini. Ciascun trattamento è stato confrontato con il relativo controllo non trattato. Esperimenti esplorativi separati di controllo della fluorescenza hanno evidenziato contributi non piastrinici alla FI; questa va quindi interpretata insieme a %SAC, MTA e immagini. L’analisi automatica ha mostrato buona concordanza con quella manuale per %SAC, meno precisa per i valori elevati di MTA. Il sangue non trattato ha mostrato deposizione piastrinica a entrambi gli shear rate. A 10.000 s⁻¹ gli aggregati hanno mostrato ripetuti fenomeni di crescita, perdita, ricrescita ed embolizzazione. Caplacizumab non ha prodotto un’inibizione consistente a 1.000 s⁻¹, mentre a 10.000 s⁻¹ ha mantenuto %SAC e MTA prossimi ai valori iniziali e ridotto significativamente l’endpoint di %SAC e i valori integrati di %SAC e MTA. Glenzocimab non ha modificato significativamente endpoint o misure integrate. Alcune registrazioni con glenzocimab ad alto shear hanno mostrato fluttuazioni e lento spostamento a valle di aggregati che non rimanevano fissi in un punto della superficie, osservazioni compatibili con alterazioni del consolidamento o della persistenza. Poiché l’embolizzazione era presente anche nei controlli e non è stata quantificata, non è stato possibile dimostrare un aumento dell’instabilità specificamente associato a glenzocimab. L’imaging in vista laterale, condotto separatamente in canali PDMS-vetro rivestiti di collagene, è risultato qualitativamente fattibile, ma la proiezione e la sovrapposizione del segnale hanno impedito la quantificazione dell’altezza dei trombi. Nel complesso, i risultati supportano un ruolo critico dell’asse vWF-GPIbα nella cattura piastrinica ad alto shear e sono compatibili con un possibile contributo dei processi GPVI-dipendenti al consolidamento e alla persistenza degli aggregati dopo la deposizione iniziale.

Microfluidic investigation of shear-mediated platelet deposition and thrombus formation on polyurethane: effects of caplacizumab and glenzocimab under conditions relevant to ventricular assist devices

DRAGOTTO, MARIA ISABELLA
2025/2026

Abstract

Thrombosis in blood-contacting cardiovascular devices is governed by interactions among artificial surfaces, altered hemodynamics, and platelet-mediated mechanisms. This study investigated platelet deposition and thrombus formation on medical-grade BioSpan S polyurethane under physiological and supraphysiological shear, focusing on selective inhibition of vWF-GPIbα-mediated platelet capture and GPVI-dependent signaling. Reconstituted blood from six healthy donors was tested under paired untreated control, caplacizumab-treated, and glenzocimab-treated conditions at 1,000 and 10,000 s⁻¹ during 15-minute microfluidic perfusions. Time-resolved fluorescence intensity (FI), surface area coverage (%SAC), and mean thrombus area (MTA) were examined through kinetic profiles, 15-minute endpoints, integrated responses, and image sequences. Each treatment was analyzed separately against its paired untreated control. Separate exploratory fluorescence-background control experiments were performed. These experiments showed that FI contained time-dependent non-platelet- associated contributions, confirming the need to interpret FI, %SAC, MTA, and the images together. Validation of automated image processing against manual processing showed close agreement for %SAC, but less precise agreement for MTA at larger values. Untreated blood produced platelet deposition at both shear rates. At 10,000 s⁻¹, aggregates developed rapidly but underwent repeated growth, loss, regrowth, and embolization. Caplacizumab produced no consistent inhibition at 1,000 s⁻¹, whereas at 10,000 s⁻¹ it maintained %SAC and MTA near their initial values and significantly reduced endpoint %SAC and integrated %SAC and MTA. Glenzocimab did not significantly alter endpoint or integrated measurements at either shear rate. Several high-shear glenzocimab recordings showed repeated fluctuations and slow downstream aggregate displacement without remaining fixed at one surface location, compatible with altered consolidation or persistence. Because embolization also occurred in untreated controls and was not quantified, a glenzocimab-specific increase in instability could not be established. Side-view imaging in separate collagen-coated PDMS–glass channels was qualitatively feasible, but projection and signal overlap prevented direct thrombus-height quantification. Overall, the findings support a critical role for vWF-GPIbα in high-shear platelet capture and are consistent with a possible contribution of GPVI-dependent processes to post-recruitment aggregate consolidation and persistence.
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-ott-2026
2025/2026
La trombosi nei dispositivi cardiovascolari a contatto con il sangue deriva dall’interazione tra superfici artificiali, alterazioni emodinamiche e meccanismi piastrinici. Il presente studio ha analizzato la deposizione piastrinica e la formazione di trombi su poliuretano medicale BioSpan S in condizioni di shear fisiologico e sovrafisiologico, concentrandosi sull’inibizione della cattura piastrinica mediata da vWF-GPIbα e della segnalazione GPVI-dipendente. Sangue ricostituito di sei donatori sani è stato testato in condizioni di controllo non trattato, caplacizumab e glenzocimab a 1.000 e 10.000 s⁻¹ durante perfusioni microfluidiche di 15 minuti. Intensità di fluorescenza (FI), percentuale di area superficiale coperta (%SAC) e area media dei trombi (MTA) sono state analizzate mediante profili cinetici, valori finali, misure integrate e immagini. Ciascun trattamento è stato confrontato con il relativo controllo non trattato. Esperimenti esplorativi separati di controllo della fluorescenza hanno evidenziato contributi non piastrinici alla FI; questa va quindi interpretata insieme a %SAC, MTA e immagini. L’analisi automatica ha mostrato buona concordanza con quella manuale per %SAC, meno precisa per i valori elevati di MTA. Il sangue non trattato ha mostrato deposizione piastrinica a entrambi gli shear rate. A 10.000 s⁻¹ gli aggregati hanno mostrato ripetuti fenomeni di crescita, perdita, ricrescita ed embolizzazione. Caplacizumab non ha prodotto un’inibizione consistente a 1.000 s⁻¹, mentre a 10.000 s⁻¹ ha mantenuto %SAC e MTA prossimi ai valori iniziali e ridotto significativamente l’endpoint di %SAC e i valori integrati di %SAC e MTA. Glenzocimab non ha modificato significativamente endpoint o misure integrate. Alcune registrazioni con glenzocimab ad alto shear hanno mostrato fluttuazioni e lento spostamento a valle di aggregati che non rimanevano fissi in un punto della superficie, osservazioni compatibili con alterazioni del consolidamento o della persistenza. Poiché l’embolizzazione era presente anche nei controlli e non è stata quantificata, non è stato possibile dimostrare un aumento dell’instabilità specificamente associato a glenzocimab. L’imaging in vista laterale, condotto separatamente in canali PDMS-vetro rivestiti di collagene, è risultato qualitativamente fattibile, ma la proiezione e la sovrapposizione del segnale hanno impedito la quantificazione dell’altezza dei trombi. Nel complesso, i risultati supportano un ruolo critico dell’asse vWF-GPIbα nella cattura piastrinica ad alto shear e sono compatibili con un possibile contributo dei processi GPVI-dipendenti al consolidamento e alla persistenza degli aggregati dopo la deposizione iniziale.
File allegati
File Dimensione Formato  
2026_10_Dragotto_Tesi.pdf

accessibile in internet per tutti

Descrizione: Corpo della tesi
Dimensione 4.22 MB
Formato Adobe PDF
4.22 MB Adobe PDF Visualizza/Apri
2026_10_Dragotto_Executive Summary.pdf

accessibile in internet per tutti

Descrizione: Executive summary
Dimensione 1.04 MB
Formato Adobe PDF
1.04 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/266837