Disorders of the nervous system - often arising from disordered electrical activity of neural circuits that remains refractory to conventional pharmacological interventions - represent a primary source of long-term disability and societal strain worldwide. In this context, bidirectional neural interfaces have emerged as next-generation therapeutic bioelectronic devices capable of establishing closed-loop communication with the brain - simultaneously monitoring electrophysiological activity and delivering adaptive, therapeutic neuromodulation. However, their chronic clinical viability critically depends on implantable microelectrodes that must exhibit long-term functional stability, low interfacial impedance, and high charge-storage capacity (CSC). While conductive polymers such as PEDOT:PSS show excellent recording capabilities but tend to degrade and delaminate under repeated stimulation, non-stoichiometric, pseudocapacitive, transition-metal oxides - specifically sputtered iridium oxide films (SIROF) - offer a more stable alternative by relying on ion-coupled, surface-confined redox reactions rather than volumetric ion diffusion. Yet, their performance remains strongly coupled to deposition conditions. In this work, we studied the role of sputtering parameters, linking morphology and composition with electrochemical behavior, and built different process maps capturing the effects of transitioning from low-surface-area granular to high-surface-area dendritic SIROF and the influence of deposition conditions on coating performance. Results showed that a bilayer Ir/SIROF stack featuring a nanoporous, highly branched, dendritic surface morphology reduced PEDOT:PSS impedance by 30%, achieved an over 8-fold increase in CSC, and markedly improved stability during long-term biphasic stimulation, yielding a tunable, reproducible coating. In vivo, optimized dendritic SIROF microelectrodes maintained significantly lower chronic impedance and higher SNR over a 5-week monitoring period compared to the PEDOT:PSS control

I disturbi del sistema nervoso - spesso derivanti da anomalie nell'attività elettrica neuronale, resistente ai trattamenti farmacologici convenzionali - rappresentano una delle principali cause di disabilità e di pressione sociale nel mondo. In questo contesto, le interfacce neurali bidirezionali sono emerse come dispositivi terapeutici di nuova generazione, capaci di instaurare una comunicazione closed-loop con il cervello, monitorandone l'attività, e applicandovi in tempo reale una neuromodulazione terapeutica mirata. Tuttavia, il loro uso clinico richiede microelettrodi ad elevata stabilità, bassa impedenza di contatto ed elevata capacità di accumulo di carica (charge storage capacity, CSC). Seppure polimeri conduttivi come il PEDOT:PSS sono in grado di registrare l'attività neurale, questi tendono a degradare velocemente nel caso di stimolazione elettrica ripetuta. Particolari ossidi metallici - nello specifico i sputtered iridium oxide films (SIROF) - costituiscono un'alternativa stabile, grazie alla capacità di scambiare carica mediante reazioni redox superficiali, al contrario dei polimeri per i quali il meccanismo di scambio è la diffusione volumetrica. Ciononostante, le prestazioni dei SIROF sono fortemente vincolate ai parametri di deposizione. Nel presente lavoro, il ruolo dei parametri di sputtering è stato analizzato correlando la morfologia e la composizione chimica delle superfici al loro comportamento elettrochimico, descrivendo la transizione da film granulari a strutture dendritiche ad alta area superficiale da un punto di vista strutturale, funzionale e di processo. I risultati ottenuti dimostrano come un doppio strato Ir/SIROF, caratterizzato da una superficie dendritica, nanoporosa e ramificata, consenta di ridurre l'impedenza di contatto del 30% rispetto al PEDOT:PSS, incrementando la CSC di oltre 8 volte, e di migliorare la stabilità a seguito di stimolazione elettrica prolungata. In vivo, i microelettrodi in SIROF hanno registrato un miglior SNR ed un'impedenza inferiore nell'arco delle 5 settimane di monitoraggio rispetto al gruppo di controllo in PEDOT:PSS.

Characterizing nanoscale morphology and performance of sputtered iridium oxide coatings for neural applications

Resciniti, Leonardo
2025/2026

Abstract

Disorders of the nervous system - often arising from disordered electrical activity of neural circuits that remains refractory to conventional pharmacological interventions - represent a primary source of long-term disability and societal strain worldwide. In this context, bidirectional neural interfaces have emerged as next-generation therapeutic bioelectronic devices capable of establishing closed-loop communication with the brain - simultaneously monitoring electrophysiological activity and delivering adaptive, therapeutic neuromodulation. However, their chronic clinical viability critically depends on implantable microelectrodes that must exhibit long-term functional stability, low interfacial impedance, and high charge-storage capacity (CSC). While conductive polymers such as PEDOT:PSS show excellent recording capabilities but tend to degrade and delaminate under repeated stimulation, non-stoichiometric, pseudocapacitive, transition-metal oxides - specifically sputtered iridium oxide films (SIROF) - offer a more stable alternative by relying on ion-coupled, surface-confined redox reactions rather than volumetric ion diffusion. Yet, their performance remains strongly coupled to deposition conditions. In this work, we studied the role of sputtering parameters, linking morphology and composition with electrochemical behavior, and built different process maps capturing the effects of transitioning from low-surface-area granular to high-surface-area dendritic SIROF and the influence of deposition conditions on coating performance. Results showed that a bilayer Ir/SIROF stack featuring a nanoporous, highly branched, dendritic surface morphology reduced PEDOT:PSS impedance by 30%, achieved an over 8-fold increase in CSC, and markedly improved stability during long-term biphasic stimulation, yielding a tunable, reproducible coating. In vivo, optimized dendritic SIROF microelectrodes maintained significantly lower chronic impedance and higher SNR over a 5-week monitoring period compared to the PEDOT:PSS control
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-ott-2026
2025/2026
I disturbi del sistema nervoso - spesso derivanti da anomalie nell'attività elettrica neuronale, resistente ai trattamenti farmacologici convenzionali - rappresentano una delle principali cause di disabilità e di pressione sociale nel mondo. In questo contesto, le interfacce neurali bidirezionali sono emerse come dispositivi terapeutici di nuova generazione, capaci di instaurare una comunicazione closed-loop con il cervello, monitorandone l'attività, e applicandovi in tempo reale una neuromodulazione terapeutica mirata. Tuttavia, il loro uso clinico richiede microelettrodi ad elevata stabilità, bassa impedenza di contatto ed elevata capacità di accumulo di carica (charge storage capacity, CSC). Seppure polimeri conduttivi come il PEDOT:PSS sono in grado di registrare l'attività neurale, questi tendono a degradare velocemente nel caso di stimolazione elettrica ripetuta. Particolari ossidi metallici - nello specifico i sputtered iridium oxide films (SIROF) - costituiscono un'alternativa stabile, grazie alla capacità di scambiare carica mediante reazioni redox superficiali, al contrario dei polimeri per i quali il meccanismo di scambio è la diffusione volumetrica. Ciononostante, le prestazioni dei SIROF sono fortemente vincolate ai parametri di deposizione. Nel presente lavoro, il ruolo dei parametri di sputtering è stato analizzato correlando la morfologia e la composizione chimica delle superfici al loro comportamento elettrochimico, descrivendo la transizione da film granulari a strutture dendritiche ad alta area superficiale da un punto di vista strutturale, funzionale e di processo. I risultati ottenuti dimostrano come un doppio strato Ir/SIROF, caratterizzato da una superficie dendritica, nanoporosa e ramificata, consenta di ridurre l'impedenza di contatto del 30% rispetto al PEDOT:PSS, incrementando la CSC di oltre 8 volte, e di migliorare la stabilità a seguito di stimolazione elettrica prolungata. In vivo, i microelettrodi in SIROF hanno registrato un miglior SNR ed un'impedenza inferiore nell'arco delle 5 settimane di monitoraggio rispetto al gruppo di controllo in PEDOT:PSS.
File allegati
File Dimensione Formato  
Resciniti_Thesis+Summary.pdf

accessibile in internet per tutti a partire dal 01/10/2027

Dimensione 13.7 MB
Formato Adobe PDF
13.7 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/266880