The resilience of modern Urban Rail Transit (URT) networks is increasingly compromised by inflexible physical infrastructure during capacity shocks. Because traditional continuous-flow models obscure localized mechanical failures by distributing congestion spatially, this thesis develops a bespoke discrete-time, multi-agent computational framework to diagnose structural vulnerability within the Milan Metro system (M1, M2, M3, and M5 lines). By comparing a normative operational baseline against an artificially degraded mechanical state triggered by an exogenous delay, the digital twin generates a Subtractive Delta Matrix to mathematically isolate the network's absolute infrastructural failure limits. Results demonstrate that catastrophic failure is not uniform, but hyper-concentrated at major multi-line transfer hubs, specifically Lambrate Pacini M2 and Garibaldi M2. Under truncated mechanical supply, intermodal transfer algorithms collapse; at the systemic apex, the localized queue at Lambrate Pacini M2 reached an absolute overload of 774 stranded agents, resulting in severe spatial congestion that triggers a Level of Service (LoS) E hazard. Ultimately, this research provides a quantified diagnostic tool for infrastructural triage, empirically proving that passive operational adjustments cannot mitigate localized shocks. Securing the structural integrity of the Milan URT requires asymmetric algorithmic flow control, targeted turnstile metering, and capital-intensive architectural expansions to absorb the compounding geometry of multi-line transfers.

La resilienza delle moderne reti di Trasporto Rapido di Massa (URT) è sempre più compromessa dalla rigidità delle infrastrutture fisiche durante gli shock di capacità. Poiché i tradizionali modelli a flusso continuo oscurano i guasti localizzati distribuendo spazialmente la congestione, questa tesi sviluppa un framework computazionale multi-agente a tempo discreto per diagnosticare la vulnerabilità strutturale del sistema metropolitano di Milano (linee M1, M2, M3 e M5). Confrontando una baseline operativa normativa con uno stato meccanico degradato innescato da un ritardo esogeno, il gemello digitale genera una Matrice Delta Sottrattiva per isolare matematicamente i limiti assoluti di cedimento infrastrutturale della rete. I risultati dimostrano che il cedimento catastrofico non è uniforme, ma iper-concentrato nei principali snodi di interscambio multi-linea, in particolare Lambrate Pacini M2 e Garibaldi M2. In condizioni di fornitura meccanica troncata, gli algoritmi di trasferimento intermodale collassano; all'apice sistemico, la coda a Lambrate Pacini M2 ha raggiunto un sovraccarico assoluto di 774 passeggeri bloccati, determinando una grave congestione spaziale che innesca una condizione di pericolo di Livello di Servizio (LoS) E. In definitiva, questa ricerca fornisce uno strumento diagnostico quantificato per il triage infrastrutturale, dimostrando empiricamente che gli aggiustamenti operativi passivi non possono mitigare gli shock localizzati. Garantire l'integrità strutturale della rete URT di Milano richiede un controllo algoritmico asimmetrico dei flussi, il contingentamento mirato ai tornelli e interventi di espansione architettonica ad alta intensità di capitale per assorbire la geometria composta dei trasferimenti multi-linea.

Simulation of exogenous event effects on train delays in the underground metro system of Milan

Raheel, Muhammad Huzaifah
2025/2026

Abstract

The resilience of modern Urban Rail Transit (URT) networks is increasingly compromised by inflexible physical infrastructure during capacity shocks. Because traditional continuous-flow models obscure localized mechanical failures by distributing congestion spatially, this thesis develops a bespoke discrete-time, multi-agent computational framework to diagnose structural vulnerability within the Milan Metro system (M1, M2, M3, and M5 lines). By comparing a normative operational baseline against an artificially degraded mechanical state triggered by an exogenous delay, the digital twin generates a Subtractive Delta Matrix to mathematically isolate the network's absolute infrastructural failure limits. Results demonstrate that catastrophic failure is not uniform, but hyper-concentrated at major multi-line transfer hubs, specifically Lambrate Pacini M2 and Garibaldi M2. Under truncated mechanical supply, intermodal transfer algorithms collapse; at the systemic apex, the localized queue at Lambrate Pacini M2 reached an absolute overload of 774 stranded agents, resulting in severe spatial congestion that triggers a Level of Service (LoS) E hazard. Ultimately, this research provides a quantified diagnostic tool for infrastructural triage, empirically proving that passive operational adjustments cannot mitigate localized shocks. Securing the structural integrity of the Milan URT requires asymmetric algorithmic flow control, targeted turnstile metering, and capital-intensive architectural expansions to absorb the compounding geometry of multi-line transfers.
ING I - Scuola di Ingegneria Civile, Ambientale e Territoriale
20-ott-2026
2025/2026
La resilienza delle moderne reti di Trasporto Rapido di Massa (URT) è sempre più compromessa dalla rigidità delle infrastrutture fisiche durante gli shock di capacità. Poiché i tradizionali modelli a flusso continuo oscurano i guasti localizzati distribuendo spazialmente la congestione, questa tesi sviluppa un framework computazionale multi-agente a tempo discreto per diagnosticare la vulnerabilità strutturale del sistema metropolitano di Milano (linee M1, M2, M3 e M5). Confrontando una baseline operativa normativa con uno stato meccanico degradato innescato da un ritardo esogeno, il gemello digitale genera una Matrice Delta Sottrattiva per isolare matematicamente i limiti assoluti di cedimento infrastrutturale della rete. I risultati dimostrano che il cedimento catastrofico non è uniforme, ma iper-concentrato nei principali snodi di interscambio multi-linea, in particolare Lambrate Pacini M2 e Garibaldi M2. In condizioni di fornitura meccanica troncata, gli algoritmi di trasferimento intermodale collassano; all'apice sistemico, la coda a Lambrate Pacini M2 ha raggiunto un sovraccarico assoluto di 774 passeggeri bloccati, determinando una grave congestione spaziale che innesca una condizione di pericolo di Livello di Servizio (LoS) E. In definitiva, questa ricerca fornisce uno strumento diagnostico quantificato per il triage infrastrutturale, dimostrando empiricamente che gli aggiustamenti operativi passivi non possono mitigare gli shock localizzati. Garantire l'integrità strutturale della rete URT di Milano richiede un controllo algoritmico asimmetrico dei flussi, il contingentamento mirato ai tornelli e interventi di espansione architettonica ad alta intensità di capitale per assorbire la geometria composta dei trasferimenti multi-linea.
File allegati
File Dimensione Formato  
2026_10_RAHEEL.pdf

accessibile in internet per tutti

Descrizione: Thesis - Simulation of Exogenous Event Effects on Train Delays in The Underground Metro System of Milan
Dimensione 4.38 MB
Formato Adobe PDF
4.38 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/267005