Decarbonizing the energy sector and commercial agriculture requires scalable solutions for seasonal thermal energy storage to overcome the sharp temporal and spatial mismatch between summer energy availability and winter heating demand. In the Netherlands, commercial greenhouse operations rely heavily on natural gas for heating, facing rising tax burdens, fluctuating winter electricity prices and severe electrical grid congestion. Developed within the USES4HEAT framework, this thesis addresses these operational and environmental challenges by investigating a Medium-Temperature Aquifer Thermal Energy Storage (MT-ATES) system at the Andel demonstration site. The system integrates an open-loop wellfield, consisting of four warm wells and six cold wells targeting the second aquifer layer (storage aquifer) to supply decarbonized space heating to a commercial orchid greenhouse. To evaluate the dynamic thermal and hydraulic interactions across the subsurface porous media, wellbores and surface infrastructure, an integrated 3D numerical modeling framework was developed using the Volsung simulation software. The spatial domain (1700 m x 1200 m horizontally, 0 to -150 m vertically) was discretized using 2 m vertical layer resolution and a refined 10 m horizontal mesh surrounding the well clusters. Surface flow network optimization was executed using the Otter simulator powered by the multi-threaded Temperature Parallel Simulated Annealing with Adaptive Neighborhood (TPSAAN) algorithm across 32 parallel processing threads. Operational control was implemented via a Universal Generator unit that regulated bottomhole pressure (BHP) throttling of warm production wells to dynamically match weekly winter greenhouse heating demands ranging from 4.2 MW to 7.89 MW. Numerical simulations demonstrated stable hydraulic and thermal performance across the seasonal operating cycle, maintaining a legal pressure state where flowing wellhead pressure stays within structural safety limits. During winter heat extraction, warm production wells delivered peak thermal power outputs of 6-7.25 MW at total flow rates up to 27 kg/s with individual wellports contributing up to 24 kg/s (Port 1), 18 kg/s (Port 3) and 3.7 kg/s (Port 2). Cooled return water was reinjected across six cold wells using an 18 kg/s per well threshold (108 kg/s or 390 m3/h total system capacity), maintaining return temperature at 12.89-12.95 °C (aligning with the 13 °C design target) while warm production temperatures ranged between 30 to 50 °C. Subsurface thermal profiling confirmed the successful development and containment of the warm plume around the warm cluster (30-40 °C residual thermal footprint), with no thermal breakthrough observed between well clusters. The system achieved a Thermal Recovery Efficiency of 24.53% which reflects an intentional operational strategy and imbalance rather than thermal loss. By strategically over-injecting thermal energy during the summer charging phase, the system accumulates a net thermal surplus of 172.33 TJ within the aquifer. This unextracted heat surplus serves critical technical functions by accelerating subsurface thermal conditioning, establishing a warm residual thermal footprint around the wellfield to suppress conductive boundary heat losses, and pre-conditioning the reservoir baseline to progressively enhance recovery efficiency in subsequent cycles. This study established a verified 3D numerical baseline and operational control strategy for MT-ATES systems. By proving successful pressure regulation, dynamic load following, flow distribution and thermal plume containment, and the optimization benefits of intentional thermal over-injection, this work provides an engineering foundation for scaling MT-ATES technology in agricultural energy transitions.

La decarbonizzazione del settore energetico e dell’agricoltura commerciale richiede soluzioni scalabili per lo stoccaggio stagionale dell’energia termica, al fine di superare il marcato disallineamento temporale e spaziale tra la disponibilità energetica estiva e la domanda di riscaldamento invernale. Nei Paesi Bassi, le attività di coltivazione in serra su scala commerciale dipendono fortemente dal gas naturale per il riscaldamento e sono soggette a un crescente carico fiscale, a prezzi dell’elettricità invernale variabili e a una grave congestione della rete elettrica. Sviluppata nell’ambito del progetto USES4HEAT, questa tesi affronta tali problematiche operative e ambientali attraverso lo studio di un sistema di stoccaggio di energia termica in acquifero a media temperatura (Medium-Temperature Aquifer Thermal Energy Storage, MT-ATES) presso il sito dimostrativo di Andel. Il sistema integra un campo pozzi a circuito aperto, costituito da quattro pozzi caldi e sei pozzi freddi, che interessano il secondo strato acquifero (acquifero di stoccaggio) per fornire riscaldamento degli ambienti a basse emissioni di carbonio a una serra commerciale di orchidee. Per valutare le interazioni termo-idrauliche dinamiche nel mezzo poroso sotterraneo, nei pozzi e nelle infrastrutture di superficie, è stato sviluppato un modello numerico 3D integrato utilizzando il software di simulazione Volsung. Il dominio spaziale, con dimensioni di 1700 m × 1200 m in orizzontale e da 0 a −150 m in verticale, è stato discretizzato con una risoluzione verticale di 2 m e una griglia orizzontale raffinata di 10 m nell’area circostante i cluster di pozzi. L’ottimizzazione della rete di flusso superficiale è stata eseguita mediante il simulatore Otter, basato sull’algoritmo multi-threaded Temperature Parallel Simulated Annealing with Adaptive Neighborhood (TPSAAN), utilizzando 32 thread di elaborazione in parallelo. Il controllo operativo è stato implementato mediante un’unità Universal Generator, che ha regolato la pressione di fondo pozzo (Bottomhole Pressure, BHP) dei pozzi di produzione caldi tramite throttling, al fine di seguire dinamicamente la domanda settimanale di riscaldamento della serra durante l’inverno, compresa tra 4,2 MW e 7,89 MW. Le simulazioni numeriche hanno evidenziato prestazioni idrauliche e termiche stabili durante il ciclo operativo stagionale, mantenendo condizioni di pressione conformi ai requisiti normativi, con la pressione alla testa pozzo in condizioni di flusso entro i limiti di sicurezza strutturale. Durante l’estrazione di calore invernale, i pozzi di produzione caldi hanno raggiunto potenze termiche di picco comprese tra 6 e 7,25 MW, con portate totali fino a 27 kg/s e contributi individuali dei wellport fino a 24 kg/s (Porta 1), 18 kg/s (Porta 3) e 3,7 kg/s (Porta 2). L’acqua di ritorno raffreddata è stata reiniettata attraverso sei pozzi freddi, utilizzando una soglia di 18 kg/s per pozzo, corrispondente a una capacità complessiva del sistema di 108 kg/s o 390 m³/h. La temperatura dell’acqua di ritorno è stata mantenuta tra 12,89 e 12,95 °C, in linea con il valore di progetto di 13 °C, mentre le temperature di produzione dei pozzi caldi variavano tra 30 e 50 °C. Il profilo termico del sottosuolo ha confermato il corretto sviluppo e contenimento del pennacchio termico attorno al cluster caldo, con un’impronta termica residua compresa tra 30 e 40 °C e senza evidenza di breakthrough termico tra i cluster di pozzi. Il sistema ha raggiunto un’efficienza di recupero termico (Thermal Recovery Efficiency) del 24,53%, che riflette una strategia operativa e uno sbilanciamento intenzionali, piuttosto che una perdita termica. Attraverso una sovrainiezione strategica di energia termica durante la fase di ricarica estiva, il sistema accumula nell’acquifero un surplus termico netto di 172,33 TJ. Questo surplus di calore non estratto svolge importanti funzioni tecniche, accelerando il condizionamento termico del sottosuolo, creando un’impronta termica residua calda attorno al campo pozzi per ridurre le perdite di calore conduttive ai confini e pre-condizionando lo stato termico di base del serbatoio, con l’obiettivo di migliorare progressivamente l’efficienza di recupero nei cicli successivi. Questo studio ha definito una baseline numerica 3D verificata e una strategia di controllo operativo per i sistemi MT-ATES. Dimostrando la capacità di regolare la pressione, seguire dinamicamente il carico, distribuire le portate e contenere il pennacchio termico, nonché i benefici dell’ottimizzazione associati alla sovrainiezione termica intenzionale, il lavoro fornisce una base ingegneristica per l’implementazione su scala più ampia della tecnologia MT-ATES nel processo di transizione energetica del settore agricolo.

Integrated reservoir simulation and operational optimization of a medium-temperature ATES system in Andel, the Netherlands

OZTURK, ILAYDA MINA
2025/2026

Abstract

Decarbonizing the energy sector and commercial agriculture requires scalable solutions for seasonal thermal energy storage to overcome the sharp temporal and spatial mismatch between summer energy availability and winter heating demand. In the Netherlands, commercial greenhouse operations rely heavily on natural gas for heating, facing rising tax burdens, fluctuating winter electricity prices and severe electrical grid congestion. Developed within the USES4HEAT framework, this thesis addresses these operational and environmental challenges by investigating a Medium-Temperature Aquifer Thermal Energy Storage (MT-ATES) system at the Andel demonstration site. The system integrates an open-loop wellfield, consisting of four warm wells and six cold wells targeting the second aquifer layer (storage aquifer) to supply decarbonized space heating to a commercial orchid greenhouse. To evaluate the dynamic thermal and hydraulic interactions across the subsurface porous media, wellbores and surface infrastructure, an integrated 3D numerical modeling framework was developed using the Volsung simulation software. The spatial domain (1700 m x 1200 m horizontally, 0 to -150 m vertically) was discretized using 2 m vertical layer resolution and a refined 10 m horizontal mesh surrounding the well clusters. Surface flow network optimization was executed using the Otter simulator powered by the multi-threaded Temperature Parallel Simulated Annealing with Adaptive Neighborhood (TPSAAN) algorithm across 32 parallel processing threads. Operational control was implemented via a Universal Generator unit that regulated bottomhole pressure (BHP) throttling of warm production wells to dynamically match weekly winter greenhouse heating demands ranging from 4.2 MW to 7.89 MW. Numerical simulations demonstrated stable hydraulic and thermal performance across the seasonal operating cycle, maintaining a legal pressure state where flowing wellhead pressure stays within structural safety limits. During winter heat extraction, warm production wells delivered peak thermal power outputs of 6-7.25 MW at total flow rates up to 27 kg/s with individual wellports contributing up to 24 kg/s (Port 1), 18 kg/s (Port 3) and 3.7 kg/s (Port 2). Cooled return water was reinjected across six cold wells using an 18 kg/s per well threshold (108 kg/s or 390 m3/h total system capacity), maintaining return temperature at 12.89-12.95 °C (aligning with the 13 °C design target) while warm production temperatures ranged between 30 to 50 °C. Subsurface thermal profiling confirmed the successful development and containment of the warm plume around the warm cluster (30-40 °C residual thermal footprint), with no thermal breakthrough observed between well clusters. The system achieved a Thermal Recovery Efficiency of 24.53% which reflects an intentional operational strategy and imbalance rather than thermal loss. By strategically over-injecting thermal energy during the summer charging phase, the system accumulates a net thermal surplus of 172.33 TJ within the aquifer. This unextracted heat surplus serves critical technical functions by accelerating subsurface thermal conditioning, establishing a warm residual thermal footprint around the wellfield to suppress conductive boundary heat losses, and pre-conditioning the reservoir baseline to progressively enhance recovery efficiency in subsequent cycles. This study established a verified 3D numerical baseline and operational control strategy for MT-ATES systems. By proving successful pressure regulation, dynamic load following, flow distribution and thermal plume containment, and the optimization benefits of intentional thermal over-injection, this work provides an engineering foundation for scaling MT-ATES technology in agricultural energy transitions.
ING - Scuola di Ingegneria Industriale e dell'Informazione
20-ott-2026
2025/2026
La decarbonizzazione del settore energetico e dell’agricoltura commerciale richiede soluzioni scalabili per lo stoccaggio stagionale dell’energia termica, al fine di superare il marcato disallineamento temporale e spaziale tra la disponibilità energetica estiva e la domanda di riscaldamento invernale. Nei Paesi Bassi, le attività di coltivazione in serra su scala commerciale dipendono fortemente dal gas naturale per il riscaldamento e sono soggette a un crescente carico fiscale, a prezzi dell’elettricità invernale variabili e a una grave congestione della rete elettrica. Sviluppata nell’ambito del progetto USES4HEAT, questa tesi affronta tali problematiche operative e ambientali attraverso lo studio di un sistema di stoccaggio di energia termica in acquifero a media temperatura (Medium-Temperature Aquifer Thermal Energy Storage, MT-ATES) presso il sito dimostrativo di Andel. Il sistema integra un campo pozzi a circuito aperto, costituito da quattro pozzi caldi e sei pozzi freddi, che interessano il secondo strato acquifero (acquifero di stoccaggio) per fornire riscaldamento degli ambienti a basse emissioni di carbonio a una serra commerciale di orchidee. Per valutare le interazioni termo-idrauliche dinamiche nel mezzo poroso sotterraneo, nei pozzi e nelle infrastrutture di superficie, è stato sviluppato un modello numerico 3D integrato utilizzando il software di simulazione Volsung. Il dominio spaziale, con dimensioni di 1700 m × 1200 m in orizzontale e da 0 a −150 m in verticale, è stato discretizzato con una risoluzione verticale di 2 m e una griglia orizzontale raffinata di 10 m nell’area circostante i cluster di pozzi. L’ottimizzazione della rete di flusso superficiale è stata eseguita mediante il simulatore Otter, basato sull’algoritmo multi-threaded Temperature Parallel Simulated Annealing with Adaptive Neighborhood (TPSAAN), utilizzando 32 thread di elaborazione in parallelo. Il controllo operativo è stato implementato mediante un’unità Universal Generator, che ha regolato la pressione di fondo pozzo (Bottomhole Pressure, BHP) dei pozzi di produzione caldi tramite throttling, al fine di seguire dinamicamente la domanda settimanale di riscaldamento della serra durante l’inverno, compresa tra 4,2 MW e 7,89 MW. Le simulazioni numeriche hanno evidenziato prestazioni idrauliche e termiche stabili durante il ciclo operativo stagionale, mantenendo condizioni di pressione conformi ai requisiti normativi, con la pressione alla testa pozzo in condizioni di flusso entro i limiti di sicurezza strutturale. Durante l’estrazione di calore invernale, i pozzi di produzione caldi hanno raggiunto potenze termiche di picco comprese tra 6 e 7,25 MW, con portate totali fino a 27 kg/s e contributi individuali dei wellport fino a 24 kg/s (Porta 1), 18 kg/s (Porta 3) e 3,7 kg/s (Porta 2). L’acqua di ritorno raffreddata è stata reiniettata attraverso sei pozzi freddi, utilizzando una soglia di 18 kg/s per pozzo, corrispondente a una capacità complessiva del sistema di 108 kg/s o 390 m³/h. La temperatura dell’acqua di ritorno è stata mantenuta tra 12,89 e 12,95 °C, in linea con il valore di progetto di 13 °C, mentre le temperature di produzione dei pozzi caldi variavano tra 30 e 50 °C. Il profilo termico del sottosuolo ha confermato il corretto sviluppo e contenimento del pennacchio termico attorno al cluster caldo, con un’impronta termica residua compresa tra 30 e 40 °C e senza evidenza di breakthrough termico tra i cluster di pozzi. Il sistema ha raggiunto un’efficienza di recupero termico (Thermal Recovery Efficiency) del 24,53%, che riflette una strategia operativa e uno sbilanciamento intenzionali, piuttosto che una perdita termica. Attraverso una sovrainiezione strategica di energia termica durante la fase di ricarica estiva, il sistema accumula nell’acquifero un surplus termico netto di 172,33 TJ. Questo surplus di calore non estratto svolge importanti funzioni tecniche, accelerando il condizionamento termico del sottosuolo, creando un’impronta termica residua calda attorno al campo pozzi per ridurre le perdite di calore conduttive ai confini e pre-condizionando lo stato termico di base del serbatoio, con l’obiettivo di migliorare progressivamente l’efficienza di recupero nei cicli successivi. Questo studio ha definito una baseline numerica 3D verificata e una strategia di controllo operativo per i sistemi MT-ATES. Dimostrando la capacità di regolare la pressione, seguire dinamicamente il carico, distribuire le portate e contenere il pennacchio termico, nonché i benefici dell’ottimizzazione associati alla sovrainiezione termica intenzionale, il lavoro fornisce una base ingegneristica per l’implementazione su scala più ampia della tecnologia MT-ATES nel processo di transizione energetica del settore agricolo.
File allegati
File Dimensione Formato  
2026_10_OZTURK_Thesis_01.pdf

accessibile in internet per tutti

Dimensione 8.57 MB
Formato Adobe PDF
8.57 MB Adobe PDF Visualizza/Apri
2026_10_OZTURK_Executive Summary_02.pdf

accessibile in internet per tutti

Dimensione 748.56 kB
Formato Adobe PDF
748.56 kB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/267061