Wearable inertial measurement units (IMUs) are increasingly used to objectively quantify human movement outside the laboratory, but their accuracy depends strongly on the anatomical site of placement. This work compares seven placements of Axivity AX6 sensors (ankles, feet, wrists and lumbar zone (sacrum) for estimating the duration of motor activity episodes, against an optoelectronic motion capture system (gold standard), in a sample of 27 healthy adults, across two tasks: walking at three speeds and a simulated daily-activities protocol. The ENMO metric was extracted from the raw accelerometric signal and used to detect activity episodes, which were then compared, in terms of duration, with those detected optically; detection thresholds were iteratively optimized per anatomical site, maximizing agreement (ICC) with the optical reference. The ankle and foot showed the strongest agreement (ICC 0.78-0.94), followed by the sacrum (ICC 0.71); a composite performance score (correlation, accuracy, precision) confirmed this ranking, with the dominant wrist placed clearly last. A systematic asymmetry indeed emerged at the wrist: the non-dominant side showed higher agreement than the dominant side in both tasks, with opposite error directions (over- vs under-estimation); the dominant side also exhibited persistent background noise even at rest, of physiological origin. Movement-intensity cut-points (Light/Moderate/Vigorous) were calibrated per anatomical site via Youden's index on ROC curves, using nominal walking speed as the reference, and compared against existing literature. The results indicate the ankle as the preferable placement for walking, and the non-dominant wrist as the most practicable choice for continuous whole-body monitoring, providing concrete guidance for calibrating low-cost IMU devices in paediatric clinical applications.

I sensori inerziali indossabili (IMU) sono sempre più utilizzati per quantificare oggettivamente il movimento umano fuori dal laboratorio, ma la loro accuratezza dipende fortemente dal sito anatomico di posizionamento. Questo lavoro confronta sette posizionamenti di sensori Axivity AX6 (anca, caviglie, piedi, polsi) per la stima della durata di episodi motori, rispetto a un sistema di motion capture optoelettronico (gold standard), su 27 adulti sani, tramite due task: cammino a tre velocità e simulazione di attività quotidiane. Dal segnale accelerometrico grezzo è stata estratta la metrica ENMO, con cui gli episodi di attività sono stati rilevati e confrontati, in durata, con quelli rilevati otticamente; le soglie sono state ottimizzate iterativamente per distretto, massimizzando l'accordo (ICC) col riferimento ottico. Caviglia e piede hanno mostrato l'accordo più solido (ICC 0.78-0.94), seguiti dal sacro (ICC 0.71); un punteggio di performance composito (correlazione, accuratezza, precisione) conferma questo ordinamento, con il polso dominante nettamente ultimo. Al polso è infatti emersa un'asimmetria sistematica: il lato non-dominante ha mostrato accordo superiore al dominante in entrambi i task, con errore di direzione opposta (sovrastima vs sottostima); il dominante ha inoltre un rumore di fondo persistente anche in quiete, di origine fisiologica. I cut-point di intensità (Light/Moderate/Vigorous) sono stati calibrati per distretto tramite indice di Youden su curva ROC, usando la velocità nominale come riferimento, e confrontati con la letteratura. I risultati indicano la caviglia come posizione preferibile per il cammino e il polso non-dominante come scelta più praticabile per il monitoraggio whole-body continuo, con indicazioni concrete per calibrare dispositivi IMU a basso costo in applicazioni cliniche pediatriche.

Analisi comparativa di posizionamenti di sensori indossabili per la stima della durata di episodi di attività motoria

GIORGIANI, GIULIA
2025/2026

Abstract

Wearable inertial measurement units (IMUs) are increasingly used to objectively quantify human movement outside the laboratory, but their accuracy depends strongly on the anatomical site of placement. This work compares seven placements of Axivity AX6 sensors (ankles, feet, wrists and lumbar zone (sacrum) for estimating the duration of motor activity episodes, against an optoelectronic motion capture system (gold standard), in a sample of 27 healthy adults, across two tasks: walking at three speeds and a simulated daily-activities protocol. The ENMO metric was extracted from the raw accelerometric signal and used to detect activity episodes, which were then compared, in terms of duration, with those detected optically; detection thresholds were iteratively optimized per anatomical site, maximizing agreement (ICC) with the optical reference. The ankle and foot showed the strongest agreement (ICC 0.78-0.94), followed by the sacrum (ICC 0.71); a composite performance score (correlation, accuracy, precision) confirmed this ranking, with the dominant wrist placed clearly last. A systematic asymmetry indeed emerged at the wrist: the non-dominant side showed higher agreement than the dominant side in both tasks, with opposite error directions (over- vs under-estimation); the dominant side also exhibited persistent background noise even at rest, of physiological origin. Movement-intensity cut-points (Light/Moderate/Vigorous) were calibrated per anatomical site via Youden's index on ROC curves, using nominal walking speed as the reference, and compared against existing literature. The results indicate the ankle as the preferable placement for walking, and the non-dominant wrist as the most practicable choice for continuous whole-body monitoring, providing concrete guidance for calibrating low-cost IMU devices in paediatric clinical applications.
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-ott-2026
2025/2026
I sensori inerziali indossabili (IMU) sono sempre più utilizzati per quantificare oggettivamente il movimento umano fuori dal laboratorio, ma la loro accuratezza dipende fortemente dal sito anatomico di posizionamento. Questo lavoro confronta sette posizionamenti di sensori Axivity AX6 (anca, caviglie, piedi, polsi) per la stima della durata di episodi motori, rispetto a un sistema di motion capture optoelettronico (gold standard), su 27 adulti sani, tramite due task: cammino a tre velocità e simulazione di attività quotidiane. Dal segnale accelerometrico grezzo è stata estratta la metrica ENMO, con cui gli episodi di attività sono stati rilevati e confrontati, in durata, con quelli rilevati otticamente; le soglie sono state ottimizzate iterativamente per distretto, massimizzando l'accordo (ICC) col riferimento ottico. Caviglia e piede hanno mostrato l'accordo più solido (ICC 0.78-0.94), seguiti dal sacro (ICC 0.71); un punteggio di performance composito (correlazione, accuratezza, precisione) conferma questo ordinamento, con il polso dominante nettamente ultimo. Al polso è infatti emersa un'asimmetria sistematica: il lato non-dominante ha mostrato accordo superiore al dominante in entrambi i task, con errore di direzione opposta (sovrastima vs sottostima); il dominante ha inoltre un rumore di fondo persistente anche in quiete, di origine fisiologica. I cut-point di intensità (Light/Moderate/Vigorous) sono stati calibrati per distretto tramite indice di Youden su curva ROC, usando la velocità nominale come riferimento, e confrontati con la letteratura. I risultati indicano la caviglia come posizione preferibile per il cammino e il polso non-dominante come scelta più praticabile per il monitoraggio whole-body continuo, con indicazioni concrete per calibrare dispositivi IMU a basso costo in applicazioni cliniche pediatriche.
File allegati
File Dimensione Formato  
2026_10_Giorgiani.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: Testo della Tesi
Dimensione 3.87 MB
Formato Adobe PDF
3.87 MB Adobe PDF   Visualizza/Apri
2026_10_Giorgiani_Executive_Summary.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: Executive Summary
Dimensione 810.79 kB
Formato Adobe PDF
810.79 kB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/267064