Ascending thoracic aortic aneurysm (aTAA) is standardly treated by replacing the diseased segment with a Dacron prosthetic graft. Although this surgery prevents major life-threatening complications, the compliance mismatch between prosthetic and native tissue may result in altered hemodynamic in the downstream aorta. This Master’s thesis projects aims to investigate these effects using patient-specific Fluid–Structure Interaction (FSI) modelling in a prospective cohort of 20 patients undergoing elective ascending aortic replacement. Pre- and post-operative models were generated by integrating anatomical imaging, 4D Flow CMR, Cine MRI and clinical blood-pressure measurements. Patient-specific inlet velocity profiles, Windkessel outlet conditions accounting for resistance and compliance of the downstream circuit, and regional wall mechanical properties were prescribed. Additionally, post-operative models included the Dacron graft and an intermediate transition region. Model accuracy was assessed against in-vivo pressure and descending-aortic flow measurements, obtaining median relative errors of approximately 5% and 19%, respectively. Post-operative changes were investigated through local pulse wave velocity (PWV), conventional wall shear stress (WSS) indices, and also by comparing the Eulerian WSS topological skeleton with Lagrangian near-wall transport metrics, obtained by FSI-extracted data. These complementary analyses demonstrated that graft implantation produces bio-mechanical and hemodynamic alterations extending beyond the prosthetic segment into the native distal aorta, particularly in the isthmus region. Stratification by follow-up time, although exploratory, suggested that some alterations were more pronounced early after surgery, while others, such as the increased topological heterogeneity, persisted, with PWV changes progressively shifting from the isthmus toward the descending aorta. Overall, these findings suggest that the downstream response to ascending aortic grafting may evolve over time and highlight the value of patient-specific FSI for characterising the consequences of graft-induced compliance mismatch.

L’aneurisma dell’aorta toracica ascendente (aTAA) viene trattato di norma sostituendo il tratto patologico con una protesi in Dacron. Sebbene l’intervento prevenga complicanze potenzialmente fatali, la diversa compliance tra la protesi, più rigida, e il tessuto nativo può alterare l’emodinamica dell’aorta a valle. Questa tesi indaga tali effetti attraverso modelli di interazione fluido-struttura (FSI) paziente-specifici, applicati a una coorte prospettica di 20 pazienti sottoposti a sostituzione dell’aorta ascendente. I modelli pre- e post-operatori sono stati sviluppati integrando imaging anatomico, 4D Flow CMR, Cine MRI e misure non invasive di pressione arteriosa. In inlet sono stati imposti profili di velocità paziente-specifici e in outlet condizioni di Windkessel calibrate automaticamente. Le proprietà meccaniche della parete vascolare sono state definite per ogni regione, includendo la protesi in Dacron nei modelli post-operatori. L’accuratezza dei modelli è stata verificata rispetto ai dati in-vivo, con errori relativi mediani di circa il 5% sulla pressione sistolica e del 19% sulla portata in aorta discendente. Le variazioni post-operatorie nell’istmo e nell’aorta discendente sono state valutate tramite Pulse Wave Velocity (PWV), indici fluidodinamici e strutturali, e mediante il confronto tra lo scheletro topologico euleriano del WSS e metriche lagrangiane di trasporto in prossimità della parete. L’impianto della protesi ha prodotto alterazioni che si estendono oltre il tratto protesico, coinvolgendo l’aorta nativa e in particolare l’istmo. In questa regione WSS, TAWSS e OSI sono aumentati significativamente, insieme a una topologia del WSS più eterogenea e a un maggior numero di punti fissi e di sella. Le variazioni di PWV, dipendenti dal metodo di stima, suggeriscono una ridistribuzione delle onde riflesse indotta dalla protesi. L’analisi lagrangiana ha poi evidenziato un trasporto di parete più rapido. Inoltre, le strutture dello scheletro topologico euleriano sono risultate spazialmente più coerenti con le regioni ad alto tempo di esposizione (WSSET) rispetto a quelle con alto tempo di residenza (RRT). La riduzione di overlap nel post-operatorio suggerisce però che, per stime quantitative, l’analisi lagrangiana resti preferibile. La stratificazione della coorte sulla base del tempo di follow-up, pur avendo carattere esplorativo, ha indicato che alcune alterazioni sono più marcate nelle prime fasi post-operatorie. Altre, come l’aumento dell’eterogeneità topologica, persistono nel tempo, mentre le variazioni di PWV si spostano progressivamente dall’istmo verso l’aorta discendente. Nel complesso, i risultati suggeriscono che la risposta dell’aorta a valle della sostituzione protesica possa evolvere nel tempo, e sottolineano l’importanza di modelli FSI paziente-specifici nel caratterizzare le conseguenze del compliance mismatch indotto dal graft.

From from pulse wave propagation to near-wall flow: a cohort-based patient-specific FSI study to assess the downstream effects of ascending aortic graft implantation

Benedetti, Giulia
2025/2026

Abstract

Ascending thoracic aortic aneurysm (aTAA) is standardly treated by replacing the diseased segment with a Dacron prosthetic graft. Although this surgery prevents major life-threatening complications, the compliance mismatch between prosthetic and native tissue may result in altered hemodynamic in the downstream aorta. This Master’s thesis projects aims to investigate these effects using patient-specific Fluid–Structure Interaction (FSI) modelling in a prospective cohort of 20 patients undergoing elective ascending aortic replacement. Pre- and post-operative models were generated by integrating anatomical imaging, 4D Flow CMR, Cine MRI and clinical blood-pressure measurements. Patient-specific inlet velocity profiles, Windkessel outlet conditions accounting for resistance and compliance of the downstream circuit, and regional wall mechanical properties were prescribed. Additionally, post-operative models included the Dacron graft and an intermediate transition region. Model accuracy was assessed against in-vivo pressure and descending-aortic flow measurements, obtaining median relative errors of approximately 5% and 19%, respectively. Post-operative changes were investigated through local pulse wave velocity (PWV), conventional wall shear stress (WSS) indices, and also by comparing the Eulerian WSS topological skeleton with Lagrangian near-wall transport metrics, obtained by FSI-extracted data. These complementary analyses demonstrated that graft implantation produces bio-mechanical and hemodynamic alterations extending beyond the prosthetic segment into the native distal aorta, particularly in the isthmus region. Stratification by follow-up time, although exploratory, suggested that some alterations were more pronounced early after surgery, while others, such as the increased topological heterogeneity, persisted, with PWV changes progressively shifting from the isthmus toward the descending aorta. Overall, these findings suggest that the downstream response to ascending aortic grafting may evolve over time and highlight the value of patient-specific FSI for characterising the consequences of graft-induced compliance mismatch.
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-ott-2026
2025/2026
L’aneurisma dell’aorta toracica ascendente (aTAA) viene trattato di norma sostituendo il tratto patologico con una protesi in Dacron. Sebbene l’intervento prevenga complicanze potenzialmente fatali, la diversa compliance tra la protesi, più rigida, e il tessuto nativo può alterare l’emodinamica dell’aorta a valle. Questa tesi indaga tali effetti attraverso modelli di interazione fluido-struttura (FSI) paziente-specifici, applicati a una coorte prospettica di 20 pazienti sottoposti a sostituzione dell’aorta ascendente. I modelli pre- e post-operatori sono stati sviluppati integrando imaging anatomico, 4D Flow CMR, Cine MRI e misure non invasive di pressione arteriosa. In inlet sono stati imposti profili di velocità paziente-specifici e in outlet condizioni di Windkessel calibrate automaticamente. Le proprietà meccaniche della parete vascolare sono state definite per ogni regione, includendo la protesi in Dacron nei modelli post-operatori. L’accuratezza dei modelli è stata verificata rispetto ai dati in-vivo, con errori relativi mediani di circa il 5% sulla pressione sistolica e del 19% sulla portata in aorta discendente. Le variazioni post-operatorie nell’istmo e nell’aorta discendente sono state valutate tramite Pulse Wave Velocity (PWV), indici fluidodinamici e strutturali, e mediante il confronto tra lo scheletro topologico euleriano del WSS e metriche lagrangiane di trasporto in prossimità della parete. L’impianto della protesi ha prodotto alterazioni che si estendono oltre il tratto protesico, coinvolgendo l’aorta nativa e in particolare l’istmo. In questa regione WSS, TAWSS e OSI sono aumentati significativamente, insieme a una topologia del WSS più eterogenea e a un maggior numero di punti fissi e di sella. Le variazioni di PWV, dipendenti dal metodo di stima, suggeriscono una ridistribuzione delle onde riflesse indotta dalla protesi. L’analisi lagrangiana ha poi evidenziato un trasporto di parete più rapido. Inoltre, le strutture dello scheletro topologico euleriano sono risultate spazialmente più coerenti con le regioni ad alto tempo di esposizione (WSSET) rispetto a quelle con alto tempo di residenza (RRT). La riduzione di overlap nel post-operatorio suggerisce però che, per stime quantitative, l’analisi lagrangiana resti preferibile. La stratificazione della coorte sulla base del tempo di follow-up, pur avendo carattere esplorativo, ha indicato che alcune alterazioni sono più marcate nelle prime fasi post-operatorie. Altre, come l’aumento dell’eterogeneità topologica, persistono nel tempo, mentre le variazioni di PWV si spostano progressivamente dall’istmo verso l’aorta discendente. Nel complesso, i risultati suggeriscono che la risposta dell’aorta a valle della sostituzione protesica possa evolvere nel tempo, e sottolineano l’importanza di modelli FSI paziente-specifici nel caratterizzare le conseguenze del compliance mismatch indotto dal graft.
File allegati
File Dimensione Formato  
2026_10_Benedetti_Executive_Summary.pdf

accessibile in internet per tutti

Descrizione: Executive Summary
Dimensione 929.87 kB
Formato Adobe PDF
929.87 kB Adobe PDF Visualizza/Apri
2026_10_Benedetti_Tesi.pdf

accessibile in internet per tutti

Descrizione: Tesi
Dimensione 14.19 MB
Formato Adobe PDF
14.19 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/267100