Cyclist’s palsy is a compression neuropathy of the ulnar nerve associated with sustained mechanical loading at the hand–handlebar interface during cycling activity. Current diagnostic approaches primarily identify only after neurological impairment development, while direct monitoring of the mechanical exposure responsible for nerve compression remains limited. This thesis investigates the feasibility of integrating Fiber Bragg Grating (FBG) sensors into a thin wearable multilayer device designed to provide spatial information on loading across the specific region of the hand palm subjected to critical pressure. The mechanical behaviour of the pad was first investigated through finite element simulations in ANSYS®, with particular attention to material selection, layer thickness, and infill density. Based on the results, a multilayer sensing pad was fabricated using a 1 mm thermoplastic polyurethane (TPU), shore A98 sensing layer containing two optical fibers, each incorporating three FBG sensing elements, and a 3 mm Dragon Skin™ 00-10 silicone cushioning layer. The resulting device contained six distributed sensing locations across the target anatomical region. The fabricated pad was subsequently characterized under mechanical, thermal, and waterexposure conditions. Mechanical loading tests were performed at approximately 25 ◦C and 35 ◦C using a calibrated conical indenter over pressure levels ranging from approximately 25 to 300 kPa. The six sensing elements exhibited different pressure sensitivities depending on their position and temperature, with values ranging from approximately 0.22 to 1.11 pm/kPa. At 25 ◦C, the mechanical response showed non-uniform sensitivity and measurable coupling between neighbouring sensing regions, while the 35 ◦C condition produced a more spatially consistent response, with the directly loaded sensor becoming dominant for all six loading locations. Crosstalk nevertheless remained present, confirming that deformation was transmitted through the compliant multilayer structure. Thermal characterization between 25 ◦C and 40 ◦C showed that all six FBG sensing elements exhibited an approximately linear temperature response, with sensitivities ranging from about 9.11 to 16.70 pm/◦C. The thermal contribution was therefore of the same order of magnitude as the mechanically induced wavelength shifts, demonstrating that temperature compensation is necessary for quantitative pressure estimation. During a 30-minute water immersion test, all six FBG channels remained continuously trackable. The response showed an initial negative wavelength shift followed by a slower stabilization phase, with residual drift after approximately 800 s remaining substantially smaller than the initial transient response. Finally, a preliminary hand–handlebar test was performed in the drops and tops positions. The pad produced distinguishable spatial response patterns across the six sensing locations, demonstrating its ability to detect changes in hand loading configuration. The experiment also showed that the orientation of the multilayer structure strongly influenced the measured response. Because the wearable test involved distributed hand loading and an uncompensated thermal contribution, the resulting pressure maps were interpreted as estimates of the relative spatial distribution of loading rather than as validated absolute pressure measurements. Overall, the results demonstrate the feasibility of embedding a distributed FBG sensing array within a thin wearable pad for monitoring mechanical loading at the hand–handlebar interface. The prototype remained operational during mechanical, thermal, moisture, and preliminary wearable testing, while also revealing the main limitations that must be addressed before quantitative pressure measurements can be obtained reliably. The work therefore provides a proof of concept and a foundation for the further development of an FBG-based system for studying and potentially reducing cycling-related ulnar nerve compression.

La paralisi del ciclista è una neuropatia da compressione del nervo ulnare associata a un carico meccanico prolungato all’interfaccia mano–manubrio durante l’attività ciclistica. Gli attuali approcci diagnostici consentono principalmente di identificare il problema solo dopo lo sviluppo di un danno neurologico, mentre il monitoraggio diretto dell’esposizione meccanica responsabile della compressione nervosa rimane limitato. Questa tesi analizza la fattibilità dell’integrazione di sensori a reticolo di Bragg in fibra ottica (Fiber Bragg Grating, FBG) all’interno di un dispositivo indossabile multistrato e sottile, progettato per fornire informazioni spaziali sulla distribuzione del carico nella specifica regione del palmo della mano soggetta a pressioni critiche. Il comportamento meccanico del pad è stato inizialmente studiato mediante simulazioni agli elementi finiti in ANSYS®, con particolare attenzione alla selezione dei materiali, allo spessore degli strati e alla densità di riempimento. Sulla base dei risultati ottenuti, è stato realizzato un pad sensorizzato multistrato composto da uno strato sensibile in poliuretano termoplastico (TPU), shore A98, dello spessore di 1 mm, contenente due fibre ottiche, ciascuna dotata di tre elementi sensibili FBG, e da uno strato ammortizzante in silicone Dragon Skin™ 00-10 dello spessore di 3 mm. Il dispositivo risultante comprendeva sei punti di misura distribuiti nella regione anatomica di interesse. Il pad realizzato è stato successivamente caratterizzato in condizioni di carico meccanico, variazione termica ed esposizione all’acqua. Le prove di carico meccanico sono state eseguite a circa 25 ◦C e 35 ◦C utilizzando un indentatore conico calibrato, per livelli di pressione compresi approssimativamente tra 25 e 300 kPa. I sei elementi sensibili hanno mostrato differenti sensibilità alla pressione in funzione della loro posizione e della temperatura, con valori compresi tra circa 0.22 e 1.11 pm/kPa. A 25 ◦C, la risposta meccanica ha evidenziato una sensibilità non uniforme e un accoppiamento misurabile tra regioni sensibili adiacenti, mentre a 35 ◦C è stata osservata una risposta spazialmente più uniforme, con il sensore direttamente sottoposto a carico che risultava dominante in tutte e sei le posizioni di applicazione. Il crosstalk è tuttavia rimasto presente, confermando che la deformazione veniva trasmessa attraverso la struttura multistrato deformabile. La caratterizzazione termica tra 25 ◦C e 40 ◦C ha mostrato che tutti e sei gli elementi FBG presentavano una risposta alla temperatura approssimativamente lineare, con sensibilità comprese tra circa 9.11 e 16.70 pm/◦C. Il contributo termico risultava quindi dello stesso ordine di grandezza delle variazioni di lunghezza d’onda indotte meccanicamente, dimostrando la necessità di una compensazione della temperatura per ottenere una stima quantitativa della pressione. Durante una prova di immersione in acqua della durata di 30 minuti, tutti e sei i canali FBG sono rimasti continuamente rilevabili. La risposta ha mostrato inizialmente uno spostamento negativo della lunghezza d’onda, seguito da una fase di stabilizzazione più lenta, con una deriva residua dopo circa 800 s significativamente inferiore rispetto alla risposta transitoria iniziale. Infine, è stata eseguita una prova preliminare mano–manubrio nelle posizioni drops e tops. Il pad ha prodotto pattern di risposta spaziale distinguibili nei sei punti di misura, dimostrando la capacità del sistema di rilevare variazioni nella configurazione del carico della mano. L’esperimento ha inoltre evidenziato come l’orientamento della struttura multistrato influenzasse in modo significativo la risposta misurata. Poiché il test indossabile prevedeva un carico distribuito della mano e un contributo termico non compensato, le mappe di pressione risultanti sono state interpretate come stime della distribuzione spaziale relativa del carico, piuttosto che come misure validate della pressione assoluta. Nel complesso, i risultati dimostrano la fattibilità dell’integrazione di una matrice distribuita di sensori FBG all’interno di un pad indossabile sottile per il monitoraggio del carico meccanico all’interfaccia mano–manubrio. Il prototipo è rimasto operativo durante le prove meccaniche, termiche, di esposizione all’umidità e durante i test indossabili preliminari, mettendo al contempo in evidenza i principali limiti che dovranno essere affrontati prima di poter ottenere misure quantitative della pressione in modo affidabile. Il presente lavoro costituisce quindi una prova di concetto e una base per lo sviluppo futuro di un sistema basato su sensori FBG per lo studio e la possibile riduzione della compressione del nervo ulnare associata al ciclismo.

Fiber Bragg grating-based pressure monitoring wearable device for injury prevention in cycling

MATOSSIAN, CHRIS
2025/2026

Abstract

Cyclist’s palsy is a compression neuropathy of the ulnar nerve associated with sustained mechanical loading at the hand–handlebar interface during cycling activity. Current diagnostic approaches primarily identify only after neurological impairment development, while direct monitoring of the mechanical exposure responsible for nerve compression remains limited. This thesis investigates the feasibility of integrating Fiber Bragg Grating (FBG) sensors into a thin wearable multilayer device designed to provide spatial information on loading across the specific region of the hand palm subjected to critical pressure. The mechanical behaviour of the pad was first investigated through finite element simulations in ANSYS®, with particular attention to material selection, layer thickness, and infill density. Based on the results, a multilayer sensing pad was fabricated using a 1 mm thermoplastic polyurethane (TPU), shore A98 sensing layer containing two optical fibers, each incorporating three FBG sensing elements, and a 3 mm Dragon Skin™ 00-10 silicone cushioning layer. The resulting device contained six distributed sensing locations across the target anatomical region. The fabricated pad was subsequently characterized under mechanical, thermal, and waterexposure conditions. Mechanical loading tests were performed at approximately 25 ◦C and 35 ◦C using a calibrated conical indenter over pressure levels ranging from approximately 25 to 300 kPa. The six sensing elements exhibited different pressure sensitivities depending on their position and temperature, with values ranging from approximately 0.22 to 1.11 pm/kPa. At 25 ◦C, the mechanical response showed non-uniform sensitivity and measurable coupling between neighbouring sensing regions, while the 35 ◦C condition produced a more spatially consistent response, with the directly loaded sensor becoming dominant for all six loading locations. Crosstalk nevertheless remained present, confirming that deformation was transmitted through the compliant multilayer structure. Thermal characterization between 25 ◦C and 40 ◦C showed that all six FBG sensing elements exhibited an approximately linear temperature response, with sensitivities ranging from about 9.11 to 16.70 pm/◦C. The thermal contribution was therefore of the same order of magnitude as the mechanically induced wavelength shifts, demonstrating that temperature compensation is necessary for quantitative pressure estimation. During a 30-minute water immersion test, all six FBG channels remained continuously trackable. The response showed an initial negative wavelength shift followed by a slower stabilization phase, with residual drift after approximately 800 s remaining substantially smaller than the initial transient response. Finally, a preliminary hand–handlebar test was performed in the drops and tops positions. The pad produced distinguishable spatial response patterns across the six sensing locations, demonstrating its ability to detect changes in hand loading configuration. The experiment also showed that the orientation of the multilayer structure strongly influenced the measured response. Because the wearable test involved distributed hand loading and an uncompensated thermal contribution, the resulting pressure maps were interpreted as estimates of the relative spatial distribution of loading rather than as validated absolute pressure measurements. Overall, the results demonstrate the feasibility of embedding a distributed FBG sensing array within a thin wearable pad for monitoring mechanical loading at the hand–handlebar interface. The prototype remained operational during mechanical, thermal, moisture, and preliminary wearable testing, while also revealing the main limitations that must be addressed before quantitative pressure measurements can be obtained reliably. The work therefore provides a proof of concept and a foundation for the further development of an FBG-based system for studying and potentially reducing cycling-related ulnar nerve compression.
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-ott-2026
2025/2026
La paralisi del ciclista è una neuropatia da compressione del nervo ulnare associata a un carico meccanico prolungato all’interfaccia mano–manubrio durante l’attività ciclistica. Gli attuali approcci diagnostici consentono principalmente di identificare il problema solo dopo lo sviluppo di un danno neurologico, mentre il monitoraggio diretto dell’esposizione meccanica responsabile della compressione nervosa rimane limitato. Questa tesi analizza la fattibilità dell’integrazione di sensori a reticolo di Bragg in fibra ottica (Fiber Bragg Grating, FBG) all’interno di un dispositivo indossabile multistrato e sottile, progettato per fornire informazioni spaziali sulla distribuzione del carico nella specifica regione del palmo della mano soggetta a pressioni critiche. Il comportamento meccanico del pad è stato inizialmente studiato mediante simulazioni agli elementi finiti in ANSYS®, con particolare attenzione alla selezione dei materiali, allo spessore degli strati e alla densità di riempimento. Sulla base dei risultati ottenuti, è stato realizzato un pad sensorizzato multistrato composto da uno strato sensibile in poliuretano termoplastico (TPU), shore A98, dello spessore di 1 mm, contenente due fibre ottiche, ciascuna dotata di tre elementi sensibili FBG, e da uno strato ammortizzante in silicone Dragon Skin™ 00-10 dello spessore di 3 mm. Il dispositivo risultante comprendeva sei punti di misura distribuiti nella regione anatomica di interesse. Il pad realizzato è stato successivamente caratterizzato in condizioni di carico meccanico, variazione termica ed esposizione all’acqua. Le prove di carico meccanico sono state eseguite a circa 25 ◦C e 35 ◦C utilizzando un indentatore conico calibrato, per livelli di pressione compresi approssimativamente tra 25 e 300 kPa. I sei elementi sensibili hanno mostrato differenti sensibilità alla pressione in funzione della loro posizione e della temperatura, con valori compresi tra circa 0.22 e 1.11 pm/kPa. A 25 ◦C, la risposta meccanica ha evidenziato una sensibilità non uniforme e un accoppiamento misurabile tra regioni sensibili adiacenti, mentre a 35 ◦C è stata osservata una risposta spazialmente più uniforme, con il sensore direttamente sottoposto a carico che risultava dominante in tutte e sei le posizioni di applicazione. Il crosstalk è tuttavia rimasto presente, confermando che la deformazione veniva trasmessa attraverso la struttura multistrato deformabile. La caratterizzazione termica tra 25 ◦C e 40 ◦C ha mostrato che tutti e sei gli elementi FBG presentavano una risposta alla temperatura approssimativamente lineare, con sensibilità comprese tra circa 9.11 e 16.70 pm/◦C. Il contributo termico risultava quindi dello stesso ordine di grandezza delle variazioni di lunghezza d’onda indotte meccanicamente, dimostrando la necessità di una compensazione della temperatura per ottenere una stima quantitativa della pressione. Durante una prova di immersione in acqua della durata di 30 minuti, tutti e sei i canali FBG sono rimasti continuamente rilevabili. La risposta ha mostrato inizialmente uno spostamento negativo della lunghezza d’onda, seguito da una fase di stabilizzazione più lenta, con una deriva residua dopo circa 800 s significativamente inferiore rispetto alla risposta transitoria iniziale. Infine, è stata eseguita una prova preliminare mano–manubrio nelle posizioni drops e tops. Il pad ha prodotto pattern di risposta spaziale distinguibili nei sei punti di misura, dimostrando la capacità del sistema di rilevare variazioni nella configurazione del carico della mano. L’esperimento ha inoltre evidenziato come l’orientamento della struttura multistrato influenzasse in modo significativo la risposta misurata. Poiché il test indossabile prevedeva un carico distribuito della mano e un contributo termico non compensato, le mappe di pressione risultanti sono state interpretate come stime della distribuzione spaziale relativa del carico, piuttosto che come misure validate della pressione assoluta. Nel complesso, i risultati dimostrano la fattibilità dell’integrazione di una matrice distribuita di sensori FBG all’interno di un pad indossabile sottile per il monitoraggio del carico meccanico all’interfaccia mano–manubrio. Il prototipo è rimasto operativo durante le prove meccaniche, termiche, di esposizione all’umidità e durante i test indossabili preliminari, mettendo al contempo in evidenza i principali limiti che dovranno essere affrontati prima di poter ottenere misure quantitative della pressione in modo affidabile. Il presente lavoro costituisce quindi una prova di concetto e una base per lo sviluppo futuro di un sistema basato su sensori FBG per lo studio e la possibile riduzione della compressione del nervo ulnare associata al ciclismo.
File allegati
File Dimensione Formato  
2026_10_Matossian_Thesis.pdf

non accessibile

Descrizione: Report of the Master’s thesis on the development and characterization of a Fiber Bragg Grating (FBG)-based wearable pressure-sensing device for monitoring hand–handlebar loading and helping prevent cyclist’s palsy.
Dimensione 40.56 MB
Formato Adobe PDF
40.56 MB Adobe PDF   Visualizza/Apri
2026_10_Matossian_Executive_Summary.pdf

non accessibile

Descrizione: Executive Summary of the Master’s thesis on the development and characterization of a Fiber Bragg Grating (FBG)-based wearable pressure-sensing device for monitoring hand–handlebar loading and helping prevent cyclist’s palsy.
Dimensione 6.24 MB
Formato Adobe PDF
6.24 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/267123