Rooftop photovoltaics can connect the renovation of Soviet-era housing with the expansion of local electricity generation. A representative five-storey residential building in Kyiv is examined in three long axis orientations: east–west, north–south and southeast–northwest. South-facing racks at 15° and 35° and an orientation-specific redesigned roof produce nine configurations. Whole-module layouts establish installed capacity; PVGIS quantifies generation, while Ladybug radiation diagrams explain exposure and shading. The redesigned roofs produce 67.6–69.9 MWh/year. The east–west roof generates the most electricity, even tho 35° racks achieve the highest yield per installed kWp, they fit fewer modules. A deep retrofit combines envelope improvements, efficient household appliances and heat pumps. Annual thermal demands are 67.5 MWh for heating, 14.3 MWh for cooling and 56.2 MWh for hot water. Hourly temperature-dependent conversion gives total electricity consumption of 97.1 MWh/year, including appliances, cooking and lighting, or 57.2 kWh/m2/year. East–west roof generation equals 72.1% of this annual demand. A separate historical household-electricity benchmark provides a second comparison. Across 63 residential roof units in Vidradnyi, adapted roof surfaces accommodate 12.6 MWp and produce an estimated 12.6 GWh/year. The annual and monthly comparisons show that redesigned roofs can supply a substantial share of retrofit electricity demand, with summer surpluses and winter shortfalls supporting the case for grid-connected collective generation.

Il fotovoltaico sulle coperture può collegare la riqualificazione dell’edilizia residenziale sovietica alla produzione locale di elettricità. Un edificio rappresentativo di cinque piani a Kyiv è analizzato con asse longitudinale est–ovest, nord–sud e sudest–nordovest. Per ogni orientamento si confrontano moduli rivolti a sud su supporti a 15° e 35° e una copertura riprogettata, per un totale di nove configurazioni. Il posizionamento di moduli interi determina la potenza installata; PVGIS quantifica la produzione e i diagrammi Ladybug aiutano a interpretare esposizione e ombreggiamento. Le coperture riprogettate producono 67,6–69,9 MWh/anno. Il caso est–ovest offre la produzione maggiore, mentre i supporti a 35° hanno la resa specifica più alta ma ospitano meno moduli. La riqualificazione profonda combina miglioramenti dell’involucro, elettrodomestici efficienti e pompe di calore. I fabbisogni termici annuali sono 67,5 MWh per il riscaldamento, 14,3 MWh per il raffrescamento e 56,2 MWh per l’acqua calda sanitaria. La conversione oraria in funzione della temperatura restituisce un consumo elettrico complessivo di 97,1 MWh/anno, inclusi elettrodomestici, cottura e illuminazione, pari a 57,2 kWh/m2/anno. La copertura est–ovest produce l’equivalente del 72,1% della domanda annuale. Un riferimento storico dei consumi elettrici domestici offre un secondo confronto. A Vidradnyi, 63 unità di copertura adattate ospitano 12,6 MWp e producono circa 12,6 GWh/anno. I confronti annuali e mensili mostrano che le coperture riprogettate possono soddisfare una quota significativa del fabbisogno elettrico dopo la riqualificazione, con eccedenze estive e deficit invernali che sostengono l’opportunità di una produzione collettiva connessa alla rete.

Solar roofs for Kyiv's Khrushchevka housing : roof design, electrified retrofit and district energy potential

Bogdanenko, Oleksandra
2025/2026

Abstract

Rooftop photovoltaics can connect the renovation of Soviet-era housing with the expansion of local electricity generation. A representative five-storey residential building in Kyiv is examined in three long axis orientations: east–west, north–south and southeast–northwest. South-facing racks at 15° and 35° and an orientation-specific redesigned roof produce nine configurations. Whole-module layouts establish installed capacity; PVGIS quantifies generation, while Ladybug radiation diagrams explain exposure and shading. The redesigned roofs produce 67.6–69.9 MWh/year. The east–west roof generates the most electricity, even tho 35° racks achieve the highest yield per installed kWp, they fit fewer modules. A deep retrofit combines envelope improvements, efficient household appliances and heat pumps. Annual thermal demands are 67.5 MWh for heating, 14.3 MWh for cooling and 56.2 MWh for hot water. Hourly temperature-dependent conversion gives total electricity consumption of 97.1 MWh/year, including appliances, cooking and lighting, or 57.2 kWh/m2/year. East–west roof generation equals 72.1% of this annual demand. A separate historical household-electricity benchmark provides a second comparison. Across 63 residential roof units in Vidradnyi, adapted roof surfaces accommodate 12.6 MWp and produce an estimated 12.6 GWh/year. The annual and monthly comparisons show that redesigned roofs can supply a substantial share of retrofit electricity demand, with summer surpluses and winter shortfalls supporting the case for grid-connected collective generation.
ARC I - Scuola di Architettura Urbanistica Ingegneria delle Costruzioni
20-ott-2026
2025/2026
Il fotovoltaico sulle coperture può collegare la riqualificazione dell’edilizia residenziale sovietica alla produzione locale di elettricità. Un edificio rappresentativo di cinque piani a Kyiv è analizzato con asse longitudinale est–ovest, nord–sud e sudest–nordovest. Per ogni orientamento si confrontano moduli rivolti a sud su supporti a 15° e 35° e una copertura riprogettata, per un totale di nove configurazioni. Il posizionamento di moduli interi determina la potenza installata; PVGIS quantifica la produzione e i diagrammi Ladybug aiutano a interpretare esposizione e ombreggiamento. Le coperture riprogettate producono 67,6–69,9 MWh/anno. Il caso est–ovest offre la produzione maggiore, mentre i supporti a 35° hanno la resa specifica più alta ma ospitano meno moduli. La riqualificazione profonda combina miglioramenti dell’involucro, elettrodomestici efficienti e pompe di calore. I fabbisogni termici annuali sono 67,5 MWh per il riscaldamento, 14,3 MWh per il raffrescamento e 56,2 MWh per l’acqua calda sanitaria. La conversione oraria in funzione della temperatura restituisce un consumo elettrico complessivo di 97,1 MWh/anno, inclusi elettrodomestici, cottura e illuminazione, pari a 57,2 kWh/m2/anno. La copertura est–ovest produce l’equivalente del 72,1% della domanda annuale. Un riferimento storico dei consumi elettrici domestici offre un secondo confronto. A Vidradnyi, 63 unità di copertura adattate ospitano 12,6 MWp e producono circa 12,6 GWh/anno. I confronti annuali e mensili mostrano che le coperture riprogettate possono soddisfare una quota significativa del fabbisogno elettrico dopo la riqualificazione, con eccedenze estive e deficit invernali che sostengono l’opportunità di una produzione collettiva connessa alla rete.
File allegati
File Dimensione Formato  
2026_10_Bogdanenko.pdf

accessibile in internet per tutti

Dimensione 23.58 MB
Formato Adobe PDF
23.58 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/267327