This work presents the project carried out during a stage at the Carrier S.p.A. com- pany. The aim of this work is to analyze the influence of several types of adjustment on the performances of the system considered, comprising the building, the heating plant and the heat pump. To this purpose, diff erent simulations are carried out, during the whole heating period, through a software speci fically designed. Starting from the description of a flat in Milan, two diff erent heating plants (radiant floor or fancoil) are sized and the heat pump size is chosen. Furthermore, the hot water tank is added to the system and sized. Two models of heat pumps are considered during the analysis: the AquaSnap Junior 30RH013 and the AquaSnap PLUS Reversible 30AWH012H, both designed and manufactured by Carrier; the former is equipped with a fixed speed compressor while the latter is equipped with a variable speed compressor.

Il presente elaborato di tesi mostra il frutto di un lavoro svolto durante il tirocinio presso l'azienda Carrier S.p.A. volto ad analizzare l'influenza di differenti logiche di regolazione sulle prestazioni energetiche del sistema edificio-impianto-pompa di calore, simulandone il comportamento durante l'intero periodo di riscaldamento mediante un codice di calcolo ideato e sviluppato appositamente per lo scopo. Partendo dalla descrizione di un appartamento situato a Milano si sono dimensionati due impianti di riscaldamento (a pannelli radianti e a ventilconvettori), si è scelta la taglia della pompa di calore e si è anche considerato (e dimensionato) il serbatoio di accumulo per l'acqua calda sanitaria. Le pompe di calore utilizzate nell'analisi sono due: l'AquaSnap Junior 30RH013 e l'AquaSnap PLUS Reversible 30AWH012H entrambe progettate e realizzate da Carrier; la prima è equipaggiata con un compressore a velocità di rotazione fissa mentre la seconda con un compressore a velocità di rotazione variabile.

Analisi numerica di differenti logiche di regolazione di una pompa di calore aria-acqua

MOLTENI, MARCO
2008/2009

Abstract

This work presents the project carried out during a stage at the Carrier S.p.A. com- pany. The aim of this work is to analyze the influence of several types of adjustment on the performances of the system considered, comprising the building, the heating plant and the heat pump. To this purpose, diff erent simulations are carried out, during the whole heating period, through a software speci fically designed. Starting from the description of a flat in Milan, two diff erent heating plants (radiant floor or fancoil) are sized and the heat pump size is chosen. Furthermore, the hot water tank is added to the system and sized. Two models of heat pumps are considered during the analysis: the AquaSnap Junior 30RH013 and the AquaSnap PLUS Reversible 30AWH012H, both designed and manufactured by Carrier; the former is equipped with a fixed speed compressor while the latter is equipped with a variable speed compressor.
BIANCHI, CARLAMBROGIO
MAGNI, FILIPPO
ING IV - Facolta' di Ingegneria Industriale
3-mag-2010
2008/2009
Il presente elaborato di tesi mostra il frutto di un lavoro svolto durante il tirocinio presso l'azienda Carrier S.p.A. volto ad analizzare l'influenza di differenti logiche di regolazione sulle prestazioni energetiche del sistema edificio-impianto-pompa di calore, simulandone il comportamento durante l'intero periodo di riscaldamento mediante un codice di calcolo ideato e sviluppato appositamente per lo scopo. Partendo dalla descrizione di un appartamento situato a Milano si sono dimensionati due impianti di riscaldamento (a pannelli radianti e a ventilconvettori), si è scelta la taglia della pompa di calore e si è anche considerato (e dimensionato) il serbatoio di accumulo per l'acqua calda sanitaria. Le pompe di calore utilizzate nell'analisi sono due: l'AquaSnap Junior 30RH013 e l'AquaSnap PLUS Reversible 30AWH012H entrambe progettate e realizzate da Carrier; la prima è equipaggiata con un compressore a velocità di rotazione fissa mentre la seconda con un compressore a velocità di rotazione variabile.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
Tesi721006.pdf

Open Access dal 08/04/2013

Descrizione: Testo della tesi
Dimensione 3.38 MB
Formato Adobe PDF
3.38 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/507