According to a social-economic sustainable model, hydrogen is a clean energetic vector that,in the future it will play an important role in the transport sector and in the electric generation one with the fuel cells. Because of the equilibrium hydrogen two molecular forms, it’s necessary knowing how they influence its thermodynamic properties, in particular in the cryogenic conditions that has no a proper bibliography. The ideal specific heat capacity has a primarly role in this analysis and so its correct model from the high temperatures until the hydrogen liquefaction temperature. Given the importance of the choice of the plant for liquefying hydrogen, a comparative simulation of operation of two of the most important plants in the industry can compare the various electrical and thermal budgets to discover the most efficient.From this point of view the Quack plant requires more eletrical and thermal power than Valenti e Macchi plant.

In accordo con un modello socio-economico sostenibile, l’idrogeno è un vettore energetico pulito che,in futuro potrà trovare largo utilizzo nel settore dei trasporti o in quello della generazione di potenza tramite celle a combustibile. Date le due forme molecolari che compongono l’equilibrio idrogeno,è necessario conoscere come esse influiscono sulle sue caratteristiche termodinamiche, in particolare alle condizioni criogeniche,di cui non esiste un’adeguata bibliografia.Di prima importanza risulta essere il ruolo del calore specifico di gas ideale della sostanza e quindi la sua corretta modellizzazione da temperature elevate fino alla temperatura di liquefazione dell’idrogeno Dato l’importanza della scelta del tipo impianto per liquefare l’idrogeno, una simulazione comparativa di funzionamento di due tra i più importanti impianti del settore permette di confrontare i vari bilanci termici e elettrici e scambio termico in modo da scopire il più efficiente.Da questo punto di vista l’impianto di Quack richiede una potenza elettrica e termica più importante rispetto all’impianto di Valenti e Macchi

Simulazione al calcolatore di impianti di liquefazione dell'idrogeno

KAY YONG, EVARD OLIVIER
2010/2011

Abstract

According to a social-economic sustainable model, hydrogen is a clean energetic vector that,in the future it will play an important role in the transport sector and in the electric generation one with the fuel cells. Because of the equilibrium hydrogen two molecular forms, it’s necessary knowing how they influence its thermodynamic properties, in particular in the cryogenic conditions that has no a proper bibliography. The ideal specific heat capacity has a primarly role in this analysis and so its correct model from the high temperatures until the hydrogen liquefaction temperature. Given the importance of the choice of the plant for liquefying hydrogen, a comparative simulation of operation of two of the most important plants in the industry can compare the various electrical and thermal budgets to discover the most efficient.From this point of view the Quack plant requires more eletrical and thermal power than Valenti e Macchi plant.
ING IV - Scuola di Ingegneria Industriale
23-apr-2012
2010/2011
In accordo con un modello socio-economico sostenibile, l’idrogeno è un vettore energetico pulito che,in futuro potrà trovare largo utilizzo nel settore dei trasporti o in quello della generazione di potenza tramite celle a combustibile. Date le due forme molecolari che compongono l’equilibrio idrogeno,è necessario conoscere come esse influiscono sulle sue caratteristiche termodinamiche, in particolare alle condizioni criogeniche,di cui non esiste un’adeguata bibliografia.Di prima importanza risulta essere il ruolo del calore specifico di gas ideale della sostanza e quindi la sua corretta modellizzazione da temperature elevate fino alla temperatura di liquefazione dell’idrogeno Dato l’importanza della scelta del tipo impianto per liquefare l’idrogeno, una simulazione comparativa di funzionamento di due tra i più importanti impianti del settore permette di confrontare i vari bilanci termici e elettrici e scambio termico in modo da scopire il più efficiente.Da questo punto di vista l’impianto di Quack richiede una potenza elettrica e termica più importante rispetto all’impianto di Valenti e Macchi
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
KAY OLIVIER _10.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: SIMULAZIONE AL CALCOLARE DI IMPIANTI DI LIQUEFAZIONE DELL IDROGENO
Dimensione 1.11 MB
Formato Adobe PDF
1.11 MB Adobe PDF   Visualizza/Apri
KAY OLIVIER.pdf

solo utenti autorizzati dal 11/04/2013

Descrizione: SIMULAZIONE AL CALCOLARE DI IMPIANTI DI LIQUEFAZIONE DELL IDROGENO
Dimensione 1.2 MB
Formato Adobe PDF
1.2 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/51341