Seismic vulnerability of buildings is a fundamental component for the evaluation of seismic risk. Vulnerability may be reduced by retrofitting and strengthening interventions in order to improve the seismic response of structures. First of all, the best way to reduce the different vulnerabilities is to correctly evaluate them. A procedure for assessing the vulnerability of timber roof structures is organized in two levels. The first level collects data about characteristics and dimensions of the structure. This information is aimed at pointing out aspects related to the capability to react to seismic action, giving as well a more detailed description of the structure. The second level focuses on the main aspects already underlined in the first step. Different factors are examined, like the presence of unrestrained thrusts, the connections with the loadbearing walls, the capability of the structure of responding in both principal directions and the quality of carpentry joints and connections between timber elements. This procedure is not completely calibrated yet and further developments may derive from a larger collection of data. For this reason this evaluation method of seismic vulnerability has been applied to the timber roof of the church of Mettone, Lacchiarella (MI). In order to correctly evaluate the seismic response of the selected structure, several numerical analyses have been performed, with different calculation assumptions considering both the actual and traditional roof scheme and the original scheme, very unusual in modern construction. A comparison between the different results has been done, in order to improve the procedure with new data and observations.

La vulnerabilità sismica è una componente fondamentale per la valutazione del rischio sismico degli edifici. Questa può essere ridotta tramite interventi di rinforzo volti a migliorare la risposta sismica delle strutture. Per ridurre la vulnerabilità è necessario utilizzare criteri semplici ma efficaci di valutazione. Per le coperture lignee è disponibile una procedura organizzata in due livelli. Il primo livello consiste nella raccolta dei dati inerenti le caratteristiche e le dimensioni dei vari elementi della copertura. Questa raccolta dati è focalizzata sugli aspetti che influenzano la risposta sismica, dando un’immagine dettagliata dello stato della struttura. Il secondo livello pone maggiormente l’attenzione agli aspetti principali individuati nel primo livello. Si valutano quindi diversi fattori, tra cui la presenza o meno di dannose spinte non riprese, le condizioni delle connessioni con la muratura portante, la capacità di risposta della struttura nelle due direzioni e la fattura dei nodi e delle connessioni tra i vari elementi lignei. Questa procedura è ancora in fase di calibrazione e necessita di essere sviluppata tramite la raccolta di dati. Per questo motivo, questa procedura di valutazione della vulnerabilità è stata applicata alla copertura della chiesa di Mettone, Lacchiarella (MI), con l’ulteriore proposito di stimare la capacità della copertura di resistere all’azione sismica del sito. Al fine di valutare correttamente la risposta sismica della struttura considerata, sono state effettuate delle analisi numeriche facendo varie ipotesi di calcolo considerando sia lo schema di copertura attuale, di tipo tradizionale, che lo schema originario, alquanto inusuale nella pratica costruttiva odierna, confrontando i diversi risultati, in modo da fornire ulteriori dati e osservazioni in grado di migliorare la procedura.

Vulnerabilità sismica delle coperture a struttura lignea. Chiesa santi Pietro e Paolo a Mettone, Lacchiarella (MI)

SACCHI, DANIELE
2010/2011

Abstract

Seismic vulnerability of buildings is a fundamental component for the evaluation of seismic risk. Vulnerability may be reduced by retrofitting and strengthening interventions in order to improve the seismic response of structures. First of all, the best way to reduce the different vulnerabilities is to correctly evaluate them. A procedure for assessing the vulnerability of timber roof structures is organized in two levels. The first level collects data about characteristics and dimensions of the structure. This information is aimed at pointing out aspects related to the capability to react to seismic action, giving as well a more detailed description of the structure. The second level focuses on the main aspects already underlined in the first step. Different factors are examined, like the presence of unrestrained thrusts, the connections with the loadbearing walls, the capability of the structure of responding in both principal directions and the quality of carpentry joints and connections between timber elements. This procedure is not completely calibrated yet and further developments may derive from a larger collection of data. For this reason this evaluation method of seismic vulnerability has been applied to the timber roof of the church of Mettone, Lacchiarella (MI). In order to correctly evaluate the seismic response of the selected structure, several numerical analyses have been performed, with different calculation assumptions considering both the actual and traditional roof scheme and the original scheme, very unusual in modern construction. A comparison between the different results has been done, in order to improve the procedure with new data and observations.
PARISI, MARIA ADELAIDE
TARDINI, CHIARA
ING VI - Scuola di Ingegneria Edile-Architettura
23-apr-2012
2010/2011
La vulnerabilità sismica è una componente fondamentale per la valutazione del rischio sismico degli edifici. Questa può essere ridotta tramite interventi di rinforzo volti a migliorare la risposta sismica delle strutture. Per ridurre la vulnerabilità è necessario utilizzare criteri semplici ma efficaci di valutazione. Per le coperture lignee è disponibile una procedura organizzata in due livelli. Il primo livello consiste nella raccolta dei dati inerenti le caratteristiche e le dimensioni dei vari elementi della copertura. Questa raccolta dati è focalizzata sugli aspetti che influenzano la risposta sismica, dando un’immagine dettagliata dello stato della struttura. Il secondo livello pone maggiormente l’attenzione agli aspetti principali individuati nel primo livello. Si valutano quindi diversi fattori, tra cui la presenza o meno di dannose spinte non riprese, le condizioni delle connessioni con la muratura portante, la capacità di risposta della struttura nelle due direzioni e la fattura dei nodi e delle connessioni tra i vari elementi lignei. Questa procedura è ancora in fase di calibrazione e necessita di essere sviluppata tramite la raccolta di dati. Per questo motivo, questa procedura di valutazione della vulnerabilità è stata applicata alla copertura della chiesa di Mettone, Lacchiarella (MI), con l’ulteriore proposito di stimare la capacità della copertura di resistere all’azione sismica del sito. Al fine di valutare correttamente la risposta sismica della struttura considerata, sono state effettuate delle analisi numeriche facendo varie ipotesi di calcolo considerando sia lo schema di copertura attuale, di tipo tradizionale, che lo schema originario, alquanto inusuale nella pratica costruttiva odierna, confrontando i diversi risultati, in modo da fornire ulteriori dati e osservazioni in grado di migliorare la procedura.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2012_04_Sacchi.pdf

non accessibile

Descrizione: Testo della tesi
Dimensione 30.37 MB
Formato Adobe PDF
30.37 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/52421