The main goal of this work is the room acoustics analysis and design of a real building, a Waterpark under construction in Ticino (Switzerland), consisting of several domed spaces with different destinations (relax, entertainment, slides, pools, etc). The main dome represents the most critical environment of the whole structure, because of geometrical features (large volume, domed ceiling, concave floor) and high level of background noise. In order to find the best technical solutions for achieving a good level of acoustic comfort within the main dome of the Waterpark, the sound fields have been simulated with the aid of a specific software (ODEON 9.2). Since it requires the knowledge of the main features of all the materials inside the room, but the ceiling acoustic absorption was unknown, specific measurements have been performed in the smaller environment to evaluate it. Once all the materials have been characterized from the sound absorption point of view, the computer model has been validated and the simulation of the main dome has been performed. This allowed the determination of the principal acoustic parameters (T60, SPL, DL2), together with the analysis of possible focusing effects and the prediction of the speech intelligibility (STI). The detailed comparison of different acoustical treatment typologies has finally provided an important suggestion for the most efficient solution to be adopted at the end of the construction process.

L’obiettivo di questo lavoro consiste nell’analisi e progettazione acustica di un Acquaparco in costruzione in Ticino (Svizzera), formato da diversi edifici con copertura a cupola aventi destinazioni d’uso differenti (relax, divertimento, scivoli, piscine, etc). La cupola principale rappresenta l’ambiente con maggiori criticità ed esigenze dal profilo acustico, a causa delle sue caratteristiche geometriche (grande volume interno, copertura a cupola, base concava) e dell’alto livello di rumore di fondo. Al fine di individuare le soluzioni tecniche più adatte per raggiungere un buon grado di comfort acustico nella cupola principale, i campi acustici al suo interno sono stati simulati con l’ausilio di un software ad hoc (ODEON 9.2). Poiché esso richiede la conoscenza delle caratteristiche principali di tutti i materiali all’interno del locale, ma l’assorbimento acustico del telo di copertura non era noto, sono state effettuate misure apposite nella cupola minore per determinarlo. Non appena tutti i materiali sono stati caratterizzati dal punto di vista del fono-assorbimento, è stato validato il modello software e sono state effettuate le simulazioni acustiche della cupola principale. Queste hanno permesso la determinazione dei principali parametri dell’acustica di sala (T60, SPL, DL2), oltre all’analisi di potenziali effetti di focalizzazione e la previsione dell’intelligibilità del parlato (STI). La comparazione approfondita delle differenti tipologie di trattamento acustico ha infine fornito un valido suggerimento per la soluzione più efficiente da implementare a lavori ultimati.

Acoustic analysis and design of large domed spaces

GRECO, ANDREA EMANUELE
2011/2012

Abstract

The main goal of this work is the room acoustics analysis and design of a real building, a Waterpark under construction in Ticino (Switzerland), consisting of several domed spaces with different destinations (relax, entertainment, slides, pools, etc). The main dome represents the most critical environment of the whole structure, because of geometrical features (large volume, domed ceiling, concave floor) and high level of background noise. In order to find the best technical solutions for achieving a good level of acoustic comfort within the main dome of the Waterpark, the sound fields have been simulated with the aid of a specific software (ODEON 9.2). Since it requires the knowledge of the main features of all the materials inside the room, but the ceiling acoustic absorption was unknown, specific measurements have been performed in the smaller environment to evaluate it. Once all the materials have been characterized from the sound absorption point of view, the computer model has been validated and the simulation of the main dome has been performed. This allowed the determination of the principal acoustic parameters (T60, SPL, DL2), together with the analysis of possible focusing effects and the prediction of the speech intelligibility (STI). The detailed comparison of different acoustical treatment typologies has finally provided an important suggestion for the most efficient solution to be adopted at the end of the construction process.
BOZZOLO, DARIO
ING V - Scuola di Ingegneria dell'Informazione
4-ott-2012
2011/2012
L’obiettivo di questo lavoro consiste nell’analisi e progettazione acustica di un Acquaparco in costruzione in Ticino (Svizzera), formato da diversi edifici con copertura a cupola aventi destinazioni d’uso differenti (relax, divertimento, scivoli, piscine, etc). La cupola principale rappresenta l’ambiente con maggiori criticità ed esigenze dal profilo acustico, a causa delle sue caratteristiche geometriche (grande volume interno, copertura a cupola, base concava) e dell’alto livello di rumore di fondo. Al fine di individuare le soluzioni tecniche più adatte per raggiungere un buon grado di comfort acustico nella cupola principale, i campi acustici al suo interno sono stati simulati con l’ausilio di un software ad hoc (ODEON 9.2). Poiché esso richiede la conoscenza delle caratteristiche principali di tutti i materiali all’interno del locale, ma l’assorbimento acustico del telo di copertura non era noto, sono state effettuate misure apposite nella cupola minore per determinarlo. Non appena tutti i materiali sono stati caratterizzati dal punto di vista del fono-assorbimento, è stato validato il modello software e sono state effettuate le simulazioni acustiche della cupola principale. Queste hanno permesso la determinazione dei principali parametri dell’acustica di sala (T60, SPL, DL2), oltre all’analisi di potenziali effetti di focalizzazione e la previsione dell’intelligibilità del parlato (STI). La comparazione approfondita delle differenti tipologie di trattamento acustico ha infine fornito un valido suggerimento per la soluzione più efficiente da implementare a lavori ultimati.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2012_09_Greco Andrea Emanuele.pdf

accessibile in internet solo dagli utenti autorizzati

Descrizione: Greco Andrea Emanuele - Master Thesis in Computer Science
Dimensione 7.95 MB
Formato Adobe PDF
7.95 MB Adobe PDF   Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/64281