This work is a numerical study on natural convection from an upward-facing, horizontal heated plate. The plate, whose geometry is rectangular and with an aspect ratio of 15.17, is the upper horizontal surface of a parallelepiped protruding from an insulating base. All surfaces of the parallelepiped have the same temperature (310 K) and are cooled by air, except for the bottom horizontal surface that is insulated. The height of the vertical plates is half of the horizontal plate width. Fluent 6.3 was used to solve natural convection equations. Results showed that vertical plates affects heat transfer from horizontal plate. The mean Nusselt number of the horizontal plate is lower than results of other correlations.
È stata studiata la convezione naturale da una lastra piana orizzontale riscaldata con faccia rivolta verso l’alto. L’indagine, un’analisi numerica tridimensionale, è stata svolta con il codice commerciale Fluent 6.3. La lastra piana, di geometria rettangolare e con fattore di forma pari a 15.17, è la superficie orizzontale superiore di un parallelepipedo sporgente da una base isolante. Tutte le superfici del parallelepipedo hanno la stessa temperatura (310 K) e sono raffreddate ad aria, eccetto la superficie orizzontale inferiore che è considerata isolata termicamente. I risultati mostrano che le lastre verticali, di altezza pari a metà della larghezza della lastra piana, influenzano lo scambio termico che avviene sulla superficie della lastra orizzontale; il numero di Nusselt medio risulta minore rispetto a quello calcolato dalle altre correlazioni.
Analisi numerica tridimensionale della convezione naturale da una lastra piana orizzontale
SALVADORI, FABIO
2011/2012
Abstract
This work is a numerical study on natural convection from an upward-facing, horizontal heated plate. The plate, whose geometry is rectangular and with an aspect ratio of 15.17, is the upper horizontal surface of a parallelepiped protruding from an insulating base. All surfaces of the parallelepiped have the same temperature (310 K) and are cooled by air, except for the bottom horizontal surface that is insulated. The height of the vertical plates is half of the horizontal plate width. Fluent 6.3 was used to solve natural convection equations. Results showed that vertical plates affects heat transfer from horizontal plate. The mean Nusselt number of the horizontal plate is lower than results of other correlations.File | Dimensione | Formato | |
---|---|---|---|
2012_12_Salvadori.pdf
non accessibile
Descrizione: Testo della tesi
Dimensione
14.76 MB
Formato
Adobe PDF
|
14.76 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/71809