The DC distribution connected to AC distribution systems is currently becoming more and more interesting from both an application and a research viewpoint. This study considers a DC distribution system connected to the AC side through a VSC (Voltage Source Converter). Among the possible configurations, the set-up with the neutral point of the AC side solidly grounded and floating poles at the DC side has been studied. The main goal of this thesis has been the study of power quality, during both normal operation and faulty conditions (fault of one DC pole to ground). This study has laid foundations for the implementation of a future protection system.
L'utilizzo di reti di distribuzione in corrente continua connesse a reti in corrente alternata sta diventando sempre più oggetto di ricerca e di sviluppo nel mondo moderno. Il lavoro di tesi considera una di queste reti in cui la sezione AC è connessa alla sezione DC attraverso un convertitore VSC (Voltage Source Converter). Tra le numerose configurazioni possibili, è stata scelta quella che prevede la sezione AC con centro stella connesso francamente a terra e la sezione DC con poli flottanti. È stata posta, quindi, l'attenzione sullo studio della qualità del servizio di fornitura dell'energia elettrica sia in condizioni di normale funzionamento che in presenza di guasto verso terra, gettando le basi per l'implementazione di un sistema di protezione.
Guasti verso massa in sistemi di distribuzione con convertitori AC/DC
GUSSONI, STEFANO;BIGGI, GIACOMO
2011/2012
Abstract
The DC distribution connected to AC distribution systems is currently becoming more and more interesting from both an application and a research viewpoint. This study considers a DC distribution system connected to the AC side through a VSC (Voltage Source Converter). Among the possible configurations, the set-up with the neutral point of the AC side solidly grounded and floating poles at the DC side has been studied. The main goal of this thesis has been the study of power quality, during both normal operation and faulty conditions (fault of one DC pole to ground). This study has laid foundations for the implementation of a future protection system.File | Dimensione | Formato | |
---|---|---|---|
2012_12_Biggi_Gussoni.pdf
accessibile in internet solo dagli utenti autorizzati
Descrizione: Testo della tesi
Dimensione
99.24 MB
Formato
Adobe PDF
|
99.24 MB | Adobe PDF | Visualizza/Apri |
I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/10589/72626