The objective of this thesis is to analyze the hygrothermal behavior of a coating system ETICS (External Thermal Insulation Composite System) to evaluate possible problems over time and possible damages of the most stressed layers, which are those outside. Nevertheless we want to check if the water content and temperatures reach critical values that could possibly induce the occurrence of freeze-thaw cycles, which would eventually effect on the durability of the building component. In order to do this, we selected three cities (Milan, Oslo and Brussels), which are considered significant for temperatures and rain, and they were analyzed according to their most unfavorable exposure through the support of calculation software WUFI ®. After imposing the starting conditions, it was possible to obtain a pattern of water contents within the stratigraphy and the temperatures at various interfaces, as a function of time. The technological system analyzed, in agreement with the company Rockwool S.p.A., consists of a dual density isolation in mineral wool where coating layers are composed of mineral mortar and finish based siloxane, type Sto. Furthermore, there we managed to the develop a comparison between the proposed package and some stratigraphy, which have different insulations or plasters (EPS, rock wool mono density, plasters based on lime); so that, while analyzing the results obtained, we verified the quality of the analyzed solution.

L’obiettivo di questa tesi è quello di effettuare un’analisi igrotermica su un sistema a cappotto ETICS (External Thermal Insulation Composite System) per valutare nel tempo possibili problematiche e danneggiamenti degli strati più sollecitati, ovvero quelli esterni. Si vuole verificare , dunque, se i contenuti di acqua e le temperature raggiungono valori critici tali da indurre l’insorgere di cicli di gelo e disgelo, i quali graverebbero sulla durabilità del componente edilizio. Per far questo, sono state selezionate tre città (Milano, Oslo e Bruxelles) ritenute significative, per temperature e pioggia, ed analizzate secondo la loro esposizione più sfavorevole attraverso il supporto del software di calcolo WUFI®. Dopo aver imposto le condizioni di partenza, è stato possibile ottenere gli andamenti dei contenuti di acqua all’interno della stratigrafia e le temperature alle varie interfacce, in funzione del tempo. Il sistema tecnologico analizzato, in accordo con l’azienda Rockwool S.p.A., prevede un isolamento a doppia densità in lana minerale con strati di rivestimento con malta minerale e finitura a base silossanica ,tipo Sto. Inoltre, si è sviluppato un confronto tra il pacchetto proposto e alcune stratigrafie, le quali presentano isolanti o intonaci differenti (EPS, lana di roccia a mono densità, intonaci a base di calce); in questo modo, analizzando i risultati ottenuti, è stato possibile verificare il livello di risposta prestazionale della soluzione in analisi.

Analisi comparativa di sistemi di isolamento termico esterno a cappotto mediante simulazioni igrotermiche di calcolo in regime dinamico

GARAVAGLIA, DAVIDE;BENEGGI, ROBERTO MARIA
2012/2013

Abstract

The objective of this thesis is to analyze the hygrothermal behavior of a coating system ETICS (External Thermal Insulation Composite System) to evaluate possible problems over time and possible damages of the most stressed layers, which are those outside. Nevertheless we want to check if the water content and temperatures reach critical values that could possibly induce the occurrence of freeze-thaw cycles, which would eventually effect on the durability of the building component. In order to do this, we selected three cities (Milan, Oslo and Brussels), which are considered significant for temperatures and rain, and they were analyzed according to their most unfavorable exposure through the support of calculation software WUFI ®. After imposing the starting conditions, it was possible to obtain a pattern of water contents within the stratigraphy and the temperatures at various interfaces, as a function of time. The technological system analyzed, in agreement with the company Rockwool S.p.A., consists of a dual density isolation in mineral wool where coating layers are composed of mineral mortar and finish based siloxane, type Sto. Furthermore, there we managed to the develop a comparison between the proposed package and some stratigraphy, which have different insulations or plasters (EPS, rock wool mono density, plasters based on lime); so that, while analyzing the results obtained, we verified the quality of the analyzed solution.
GALLIANO, ROSANNA
ING VI - Scuola di Ingegneria Edile-Architettura
22-apr-2013
2012/2013
L’obiettivo di questa tesi è quello di effettuare un’analisi igrotermica su un sistema a cappotto ETICS (External Thermal Insulation Composite System) per valutare nel tempo possibili problematiche e danneggiamenti degli strati più sollecitati, ovvero quelli esterni. Si vuole verificare , dunque, se i contenuti di acqua e le temperature raggiungono valori critici tali da indurre l’insorgere di cicli di gelo e disgelo, i quali graverebbero sulla durabilità del componente edilizio. Per far questo, sono state selezionate tre città (Milano, Oslo e Bruxelles) ritenute significative, per temperature e pioggia, ed analizzate secondo la loro esposizione più sfavorevole attraverso il supporto del software di calcolo WUFI®. Dopo aver imposto le condizioni di partenza, è stato possibile ottenere gli andamenti dei contenuti di acqua all’interno della stratigrafia e le temperature alle varie interfacce, in funzione del tempo. Il sistema tecnologico analizzato, in accordo con l’azienda Rockwool S.p.A., prevede un isolamento a doppia densità in lana minerale con strati di rivestimento con malta minerale e finitura a base silossanica ,tipo Sto. Inoltre, si è sviluppato un confronto tra il pacchetto proposto e alcune stratigrafie, le quali presentano isolanti o intonaci differenti (EPS, lana di roccia a mono densità, intonaci a base di calce); in questo modo, analizzando i risultati ottenuti, è stato possibile verificare il livello di risposta prestazionale della soluzione in analisi.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
TESI FINALE.pdf

non accessibile

Descrizione: testo della tesi