POLITESI Politecnico di Milano Servizi Bibliotecari di Ateneo Servizi Bibliotecari di Ateneo
 
   ALL THESES       POST GRADUATE THESES       DOCTORAL THESES   
My POLITesi
authorized users
italiano
Please use this identifier to cite or link to this thesis: http://hdl.handle.net/10589/88824

Author: RAGAZZO, MATTEO
Supervisor: MORONI, GIOVANNI
Scientific Disciplinary Sector: ING-IND/16 TECNOLOGIE E SISTEMI DI LAVORAZIONE
Date: 18-Dec-2013
Academic year: 2012/2013
Title: Studio delle cause d'errore e verifica delle prestazioni di un impianto tomografico a raggi-X
Italian abstract: Negli ultimi anni, la computed tomography (CT), nata agli inizi degli an- ni ’70 come tecnologia per l’imaging medico diagnostico, ha fatto grandi passi anche nel campo della metrologia per misura dimensionale. Le sue peculiari- tà quali la possibilità di ricostruire geometrie interne ed esterne dell’oggetto ispezionato e l’indipendenza dalla natura delle superfici, hanno attirato l’in- teresse della comunita scientifica. Viene vista come diretto concorrente delle odierne sistemi per misura dimensionale quali le macchine di misura a coor- dinate (CMM) con tastatore tattile o laser. Tuttavia, le numerose cause di incertezza che coinvolgono l’intero processo di acquisizione, fan di essa una tecnologia difficilmente standardizzabile e tracciabile rispetto l’unità di misura fondamentale (metro). Al giorno d’oggi, non esiste una normativa internazionale per la verifica delle prestazioni di sistemi CT, ma solo delle linee guide che ricalcano le procedure applicate a CMM con tastatore dettate dallo standard ISO 10360. In questo lavoro è stato proposto un nuovo cam- pione ed è stato utilizzato per la valutazione delle prestazioni di un impianto CT industriale.
English abstract: In last years computed tomography, proposed from 70s as an imaging tech- nology for medical diagnosis, has became interesting in metrology for di- mensional measurements as well. Its peculiarities, like the capability of re- constructing both inner and outer geometries of the object inspected or the independence from the nature of the surfaces, has attracted the interest of the scientific community. CT is seen ad a direct competitor of the standard dimensional measurements systems such coordinate measurement machines (CMM) with tactile or optical probe. Nevertheless the various causes of uncertainty affecting the whole acquisition process, make CT a technolo- gy difficult to standardize . In particular, traceability to the fundamental unit of measure (meter) is difficult to guarantee. Nowadays no international standard exists regarding performance verification of a CT system. Only guidelines (VDI/VDE 2630 blatt 1.3) based on the procedure defined in the standard ISO 10360 for tactile CMMs are available. In this work a new specimen has been created and used to evaluate the performance of a CT industrial system.
Italian keywords: tomografia; CT; metrologia; misura dimensionale; x-ray; fpd; macchia focale
English keywords: tomography; CT; metrology; measure dimensional; x-ray; fpd; focal spot
Language: ita
Appears in Collections:POLITesi >Tesi Specialistiche/Magistrali

Files in This Item:

File Description SizeFormatVisibility
2013_12_Ragazzo.pdfTesto della tesi11.11 MBAdobe PDFNot accessible View/Open





 

  Support, maintenance and development by SURplus team @ CINECA- Powered by DSpace Software