The overhead high voltage lines are composed by spans and sometimes the spans are made by a bundle conductors to increase the efficiency of the system. To maintain constant the performance of the span, it‘s mandatory adopt a spacer dampers able to resist at different types of stresses coming from the wind. During the design of the double and triple spacer dumpers, many aspect were taken into account to pass the TERNA S.p.A. certification. Each test it was done on 3 different spacer dumpers to guarantee the repetition of the results. The tests done are: A. Visual inspection B. Checkondimension,materialandmass C. Testthetighteningoftheclamp'sscrew D. Test on longitudinal scroll of the clamp E. Testontorsionalscrolloftheclamp F. Short circuit test G. Flexibilitytest H. Test on corona effect and radio-interference (RIV) I. Test on the elastomers characteristics J. Check of the galvanized components K. Check of the spring and dumper characteristics L. Sub-spanoscillations M. Check the behaviour of the vibrating system with spacer dampers N. Test on electrical resistance

Le linee elettriche aeree ad alta tensione sono composte da campate e a volte le campate sono costituite da conduttori a fascio per aumentare l‘efficienza del sistema. Per mantenere le prestazioni della campata costanti è obbligatorio adottare dei distanziatori smorzanti capaci di resistere a differenti tipi di sforzo provenienti dal vento. Durante la progettazione dei distanziatori smorzanti binati e trinati sono stati presi in considerazioni diversi aspetti per superare il collaudo di TERNA S.p.A. Ogni test è stato effettuato su 3 differenti distanziatori smorzanti per garantire la ripetibilità dei risultati. I test effettuati sono: A. Esame a vista 
 B. Verificadelledimensioni,deimaterialiedellamassa
 C. Provadiserraggiodeibullonidelmorsetto
 D. Prova di scorrimento longitudinale del morsetto E. 
Provadiscorrimentoatorsionedelmorsetto
 F. Prova di corrente di corto-circuito simulato 
 G. Prove di flessibilità 
 H. Prove di effetto corona e di radio-disturbo (RIV) 
 I. Prove di caratterizzazione degli elastomeri 
 J. Verifica della zincatura a caldo 
 K. Verifica delle proprietà elastiche e smorzanti 
 L. Oscillazionidisub-campata
 M. Verifica del comportamento alle vibrazioni fascio/distanziatori- smorzatori 
 N. Prova di resistenza elettrica

Progettazione e collaudo di distanziatori smorzanti binati e trinati per conduttori a fascio

FORMENTI, LEONARDO
2012/2013

Abstract

The overhead high voltage lines are composed by spans and sometimes the spans are made by a bundle conductors to increase the efficiency of the system. To maintain constant the performance of the span, it‘s mandatory adopt a spacer dampers able to resist at different types of stresses coming from the wind. During the design of the double and triple spacer dumpers, many aspect were taken into account to pass the TERNA S.p.A. certification. Each test it was done on 3 different spacer dumpers to guarantee the repetition of the results. The tests done are: A. Visual inspection B. Checkondimension,materialandmass C. Testthetighteningoftheclamp'sscrew D. Test on longitudinal scroll of the clamp E. Testontorsionalscrolloftheclamp F. Short circuit test G. Flexibilitytest H. Test on corona effect and radio-interference (RIV) I. Test on the elastomers characteristics J. Check of the galvanized components K. Check of the spring and dumper characteristics L. Sub-spanoscillations M. Check the behaviour of the vibrating system with spacer dampers N. Test on electrical resistance
PIZZIGONI, BRUNO, ANTONIO
ING - Scuola di Ingegneria Industriale e dell'Informazione
28-apr-2014
2012/2013
Le linee elettriche aeree ad alta tensione sono composte da campate e a volte le campate sono costituite da conduttori a fascio per aumentare l‘efficienza del sistema. Per mantenere le prestazioni della campata costanti è obbligatorio adottare dei distanziatori smorzanti capaci di resistere a differenti tipi di sforzo provenienti dal vento. Durante la progettazione dei distanziatori smorzanti binati e trinati sono stati presi in considerazioni diversi aspetti per superare il collaudo di TERNA S.p.A. Ogni test è stato effettuato su 3 differenti distanziatori smorzanti per garantire la ripetibilità dei risultati. I test effettuati sono: A. Esame a vista 
 B. Verificadelledimensioni,deimaterialiedellamassa
 C. Provadiserraggiodeibullonidelmorsetto
 D. Prova di scorrimento longitudinale del morsetto E. 
Provadiscorrimentoatorsionedelmorsetto
 F. Prova di corrente di corto-circuito simulato 
 G. Prove di flessibilità 
 H. Prove di effetto corona e di radio-disturbo (RIV) 
 I. Prove di caratterizzazione degli elastomeri 
 J. Verifica della zincatura a caldo 
 K. Verifica delle proprietà elastiche e smorzanti 
 L. Oscillazionidisub-campata
 M. Verifica del comportamento alle vibrazioni fascio/distanziatori- smorzatori 
 N. Prova di resistenza elettrica
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
TESI FORMENTI 07-04.pdf

non accessibile

Descrizione: Distanziatori smorzanti binati e trinati