The aim of this work is the evaluation and the analysis of the different chemical-physical variables that can affect the emission from passive liquid areal surfaces, by means of the device called Wind Tunnel. To do so, several different compounds have been selected, each of them having different values for the chemical properties evaluated in the trial (e.g. boiling point, solubility); some of these substances have been studied either as pure compounds or in solution with water, at different concentrations. The physical parameters, influencing the VOCs volatilization under the Wind Tunnel system, that have been studied are the velocity of the air flowing through the device , in a range from 0.01 to about 0.1 m/s, the relative humidity (RH) of the sweep air flow, taking the two extreme values of this (RH 3.8% , as dry air and RH 98% as saturated air), and finally the temperature of both the liquid sources and of the sweep air flow , in a range from 10°C to 40°C . All the experimental results have been compared with previous volatilization models available in literature, whenever it has been possible.

Lo scopo del presente lavoro è la valutazione e l'analisi delle diverse variabili chimico-fisiche che possono influenzare l'emissione da sorgenti liquid areali passive, mediante l'utilizzo di un apposito sistema chiamato Wind Tunnel. A tale scopo, sono stati selezionati diversi composti, ciascuno con valori diversi per le proprietà chimiche in analisi (e.g. pressione di vaporizzazione, solubilità); alcuni di questi sono stati studiati sia come composti puri che in soluzione in acqua, a diverse concentrazioni. Le variabili fisiche, influenzanti il fenomeno di volatilizzazione sotto Wind Tunnel, sono la velocità del flusso gassoso, che lambisce la superficie, in un range da 0.01 a 0.1 m/s, l'umidità relativa (RH) del flusso, considerando i due valori estremi di aria secca (RH=3.8%) e aria satura (RH>98%), e infine la temperatura, sia del flusso che della soluzione liquida, in un range dai 10°C ai 40°C. Tutte le prove sperimentali sono state comparate con modelli di volatilizzazione precedenti, dove possibile.

Studio delle variabili chimico-fisiche controllanti nei processi di trasferimento di massa in wind tunnel

MIOLA, RICCARDO;BELLINI, ALESSIA
2016/2017

Abstract

The aim of this work is the evaluation and the analysis of the different chemical-physical variables that can affect the emission from passive liquid areal surfaces, by means of the device called Wind Tunnel. To do so, several different compounds have been selected, each of them having different values for the chemical properties evaluated in the trial (e.g. boiling point, solubility); some of these substances have been studied either as pure compounds or in solution with water, at different concentrations. The physical parameters, influencing the VOCs volatilization under the Wind Tunnel system, that have been studied are the velocity of the air flowing through the device , in a range from 0.01 to about 0.1 m/s, the relative humidity (RH) of the sweep air flow, taking the two extreme values of this (RH 3.8% , as dry air and RH 98% as saturated air), and finally the temperature of both the liquid sources and of the sweep air flow , in a range from 10°C to 40°C . All the experimental results have been compared with previous volatilization models available in literature, whenever it has been possible.
INVERNIZZI, MARZIO
ING - Scuola di Ingegneria Industriale e dell'Informazione
21-dic-2017
2016/2017
Lo scopo del presente lavoro è la valutazione e l'analisi delle diverse variabili chimico-fisiche che possono influenzare l'emissione da sorgenti liquid areali passive, mediante l'utilizzo di un apposito sistema chiamato Wind Tunnel. A tale scopo, sono stati selezionati diversi composti, ciascuno con valori diversi per le proprietà chimiche in analisi (e.g. pressione di vaporizzazione, solubilità); alcuni di questi sono stati studiati sia come composti puri che in soluzione in acqua, a diverse concentrazioni. Le variabili fisiche, influenzanti il fenomeno di volatilizzazione sotto Wind Tunnel, sono la velocità del flusso gassoso, che lambisce la superficie, in un range da 0.01 a 0.1 m/s, l'umidità relativa (RH) del flusso, considerando i due valori estremi di aria secca (RH=3.8%) e aria satura (RH>98%), e infine la temperatura, sia del flusso che della soluzione liquida, in un range dai 10°C ai 40°C. Tutte le prove sperimentali sono state comparate con modelli di volatilizzazione precedenti, dove possibile.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2017_dicembre_Bellini_Miola.pdf

Open Access dal 24/11/2018

Descrizione: testo della tesi
Dimensione 4.34 MB
Formato Adobe PDF
4.34 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/137568