This thesis work aims to analyze the effects of the use of enthalpy recuperators in AHU for use in office buildings; in particular the analyses concern the effects on thermal-igrometric conditions, in air-conditioned environments, and humidification consumption of enthalpy recovery solution, comparing it with a sensitive recovery one. The object of the study is a real office building in Milan, which has been modeled in the TRNSYS software, together with the air-conditioning systems. The purpose was to simulate the behavior of the building in different locations (Milano, Bolzano, Torino, Roma and Palermo), carrying out three dynamic simulations for each location (solution with enthalpy recovery and humidifier, with sensitive recovery and humidifier, with enthalpy recovery in the air handling units). The use of an enthalpy recovery, in AHU, significantly reduces the consumption of humidification, compared to the sensitive recovery, without negatively affecting the thermo-hygrometric conditions of the air-conditioned environments. The solution with enthalpy recovery, without humidification, is not very different from that with humidification, except for those places which have a drier climate in the winter season. The parameters of the evaluations were the humidifier's operating hours, and the hours in which the relative humidity of air-conditioned environments was within range which respects the conditions necessary for well-being and comfort of people.

Il lavoro di tesi ha l’obiettivo di analizzare gli effetti dell’utilizzo di recuperatori entalpici in UTA a servizio di edifici ad uso uffici; in particolare viene analizzato, in modo qualitativo, l’effetto del recupero entalpico sull’umidità negli ambienti climatizzati e sui consumi dell’umidificazione, confrontandolo con una soluzione a recupero sensibile. Oggetto di studio è un edificio reale di Milano, ad uso uffici, che è stato modellizzato nel software TRNSYS, assieme agli impianti di climatizzazione a servizio di esso. L’obiettivo era quello di simulare il comportamento dell’edificio in diverse località italiane (Milano, Bolzano, Torino, Roma e Palermo), effettuando tre simulazioni dinamiche per ogni località (soluzione con recupero entalpico e umidificatore, con recupero sensibile e umidificatore, con recupero entalpico nelle unità di trattamento aria). Dalle simulazione è emerso che l’adozione di un recupero entalpico nelle UTA riduce significativamente i consumi dell’umidificazione, rispetto al recupero sensibile, senza incidere negativamente sulle condizioni termo-igrometriche dei locali. La soluzione con solo recupero entalpico, senza umidificazione, risulta poco diversa da quella con umidificazione, eccezione per quelle localitàn che, nei mesi invernali, presentano un clima più secco. I parametri delle valutazioni sono stati le ore di intervento dell’umidificatore, e le ore in cui l’umidità relativa dei locali rientrava in un range di riferimento, che rispetta le condizioni di benessere e comfort.

Analisi delle prestazioni e degli effetti sull'umidità in ambiente di recuperatori entalpici rotativi in UTA a servizio di uffici

IL FORTE, STEFANO
2017/2018

Abstract

This thesis work aims to analyze the effects of the use of enthalpy recuperators in AHU for use in office buildings; in particular the analyses concern the effects on thermal-igrometric conditions, in air-conditioned environments, and humidification consumption of enthalpy recovery solution, comparing it with a sensitive recovery one. The object of the study is a real office building in Milan, which has been modeled in the TRNSYS software, together with the air-conditioning systems. The purpose was to simulate the behavior of the building in different locations (Milano, Bolzano, Torino, Roma and Palermo), carrying out three dynamic simulations for each location (solution with enthalpy recovery and humidifier, with sensitive recovery and humidifier, with enthalpy recovery in the air handling units). The use of an enthalpy recovery, in AHU, significantly reduces the consumption of humidification, compared to the sensitive recovery, without negatively affecting the thermo-hygrometric conditions of the air-conditioned environments. The solution with enthalpy recovery, without humidification, is not very different from that with humidification, except for those places which have a drier climate in the winter season. The parameters of the evaluations were the humidifier's operating hours, and the hours in which the relative humidity of air-conditioned environments was within range which respects the conditions necessary for well-being and comfort of people.
ING - Scuola di Ingegneria Industriale e dell'Informazione
25-lug-2018
2017/2018
Il lavoro di tesi ha l’obiettivo di analizzare gli effetti dell’utilizzo di recuperatori entalpici in UTA a servizio di edifici ad uso uffici; in particolare viene analizzato, in modo qualitativo, l’effetto del recupero entalpico sull’umidità negli ambienti climatizzati e sui consumi dell’umidificazione, confrontandolo con una soluzione a recupero sensibile. Oggetto di studio è un edificio reale di Milano, ad uso uffici, che è stato modellizzato nel software TRNSYS, assieme agli impianti di climatizzazione a servizio di esso. L’obiettivo era quello di simulare il comportamento dell’edificio in diverse località italiane (Milano, Bolzano, Torino, Roma e Palermo), effettuando tre simulazioni dinamiche per ogni località (soluzione con recupero entalpico e umidificatore, con recupero sensibile e umidificatore, con recupero entalpico nelle unità di trattamento aria). Dalle simulazione è emerso che l’adozione di un recupero entalpico nelle UTA riduce significativamente i consumi dell’umidificazione, rispetto al recupero sensibile, senza incidere negativamente sulle condizioni termo-igrometriche dei locali. La soluzione con solo recupero entalpico, senza umidificazione, risulta poco diversa da quella con umidificazione, eccezione per quelle localitàn che, nei mesi invernali, presentano un clima più secco. I parametri delle valutazioni sono stati le ore di intervento dell’umidificatore, e le ore in cui l’umidità relativa dei locali rientrava in un range di riferimento, che rispetta le condizioni di benessere e comfort.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2018_07_Il_Forte.pdf

accessibile in internet per tutti

Descrizione: ANALISI DELLE PRESTAZIONI E DEGLI EFFETTI SULL’UMIDITA’ IN AMBIENTE DI RECUPERATORI ENTALPICI ROTATIVI IN UTA A SERVIZIO DI UFFICI
Dimensione 4.01 MB
Formato Adobe PDF
4.01 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/141499