In this study, the seismic behavior of the ancient masonry church namely “San Carpoforo” which is located in Milan, Italy is examined. Since the seismic actions leave behind a trail of huge damage on the ancient masonry churches, and masonry churches are characterized by box behavior that is totally different from frame behavior, seismic assessment is essential, especially for the ones that are still available to be used. To be able to do that, in this study, the 3-D geometric model is discretized in ABAQUS software by using second-order tetrahedral elements (C3D10). Then, the concrete damage plasticity (CDP) model is adopted in order to reflect the behavior of the masonry. In the end, linear static analysis, and non-linear static analysis (pushover analysis) are carried out for reaching the conclusion about the situation of the church. Ultimately, static non-linear analysis results point out that the demand displacements are lower than the capacity of the structure.

In questo studio viene esaminato il comportamento sismico dell’antica chiesa in muratura denominata “San Carpoforo” che si trova a Milano, in Italia. Poiché le azioni sismiche lasciano dietro di sé una scia di ingenti danni sulle antiche chiese in muratura, e le chiese in muratura sono caratterizzate da un comportamento a scatola totalmente diverso dal comportamento a telaio, la valutazione sismica è essenziale, soprattutto per quelle che sono ancora disponibili all'uso. Per poterlo fare, in questo studio il modello geometrico 3D viene discretizzato nel software ABAQUS utilizzando elementi tetraedrici del secondo ordine (C3D10). Quindi, viene adottato il modello di plasticità del danno concreto (CDP) per riflettere il comportamento della muratura. Al termine si procede all’analisi statica lineare e statica non lineare (analisi pushover) per giungere alla conclusione sulla situazione della chiesa. In definitiva, i risultati dell’analisi statica non lineare evidenziano che gli spostamenti della domanda sono inferiori alla capacità della struttura.

A study on seismic behavior of Masonry Church in Milan, Italy by linear and non-linear analysis

Col, Mert
2021/2022

Abstract

In this study, the seismic behavior of the ancient masonry church namely “San Carpoforo” which is located in Milan, Italy is examined. Since the seismic actions leave behind a trail of huge damage on the ancient masonry churches, and masonry churches are characterized by box behavior that is totally different from frame behavior, seismic assessment is essential, especially for the ones that are still available to be used. To be able to do that, in this study, the 3-D geometric model is discretized in ABAQUS software by using second-order tetrahedral elements (C3D10). Then, the concrete damage plasticity (CDP) model is adopted in order to reflect the behavior of the masonry. In the end, linear static analysis, and non-linear static analysis (pushover analysis) are carried out for reaching the conclusion about the situation of the church. Ultimately, static non-linear analysis results point out that the demand displacements are lower than the capacity of the structure.
MAGRINELLI, ELEONORA
ING I - Scuola di Ingegneria Civile, Ambientale e Territoriale
28-apr-2022
2021/2022
In questo studio viene esaminato il comportamento sismico dell’antica chiesa in muratura denominata “San Carpoforo” che si trova a Milano, in Italia. Poiché le azioni sismiche lasciano dietro di sé una scia di ingenti danni sulle antiche chiese in muratura, e le chiese in muratura sono caratterizzate da un comportamento a scatola totalmente diverso dal comportamento a telaio, la valutazione sismica è essenziale, soprattutto per quelle che sono ancora disponibili all'uso. Per poterlo fare, in questo studio il modello geometrico 3D viene discretizzato nel software ABAQUS utilizzando elementi tetraedrici del secondo ordine (C3D10). Quindi, viene adottato il modello di plasticità del danno concreto (CDP) per riflettere il comportamento della muratura. Al termine si procede all’analisi statica lineare e statica non lineare (analisi pushover) per giungere alla conclusione sulla situazione della chiesa. In definitiva, i risultati dell’analisi statica non lineare evidenziano che gli spostamenti della domanda sono inferiori alla capacità della struttura.
File allegati
File Dimensione Formato  
A Study on Seismic Behavior of Masonry Church in Milan, Italy by Linear and Non-Linear Analysis.pdf

accessibile in internet per tutti

Dimensione 9.38 MB
Formato Adobe PDF
9.38 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/186841