The infrared gauge presents itself as an alternative to the resistive gauge due to the simplicity of use that characterizes the application of infrared compared to resistive strain gauges. Infrared gauges use the thermoelastic effect for the detection of structural deformation. In this work the choice of material with which to achieve the strain gauges fell on plastic, to eliminate the problems caused by excessive stiffness that characterizes infrared gauges made of metal. Preliminary analysis has guided the choice to Polyvinyl Chloride (PVC) and Polyamide (PA6). The strain gauges made of these materials were glued to a specimen of aluminum alloy placed under cyclic fatigue. During testing the influence of load, testing frequency and adhesives used for bonding strain gauges were verified. The results obtained showed how the use of a PVC strain gauge solves some of the problems that had come with metal strain gauges.

L'estensimetria infrarossa vuole proporsi come valida alternativa a quella resistiva grazie alla semplicità che caratterizza la messa in opera degli estensimetri infrarossi rispetto a quelli resistivi. L'estensimetria infrarossa sfrutta l'effetto termoelastico per la rilevazione delle deformazioni strutturali. In questo lavoro di tesi la scelta del materiale con cui realizzare gli estensimetri si è rivolta alla plastica, così da eliminare le problematiche dovute all'eccessiva rigidezza che caratterizza gli estensimetri infrarossi realizzati in metallo. Un'analisi preliminare ha orientato la scelta verso il Polivinilcloruro (PVC) e il Poliammide6 (PA6). Gli estensimetri realizzati con questi materiali sono stati incollati ad un provino in lega di alluminio posto in prova a fatica ciclica. Durante i test si è voluto verificare l'influenza del carico, delle frequenze di prova e degli adesivi utilizzati per l'incollaggio degli estensimetri. I risultati ottenuti hanno dimostrato come l'utilizzo di un estensimetro in PVC risolva alcune delle problematiche che si erano manifestate con gli estensimetri metallici.

Sviluppo di una tecnica di analisi termoelastica basata su estensimetri infrarossi in materia plastica

GAZZOLA, OSCAR
2009/2010

Abstract

The infrared gauge presents itself as an alternative to the resistive gauge due to the simplicity of use that characterizes the application of infrared compared to resistive strain gauges. Infrared gauges use the thermoelastic effect for the detection of structural deformation. In this work the choice of material with which to achieve the strain gauges fell on plastic, to eliminate the problems caused by excessive stiffness that characterizes infrared gauges made of metal. Preliminary analysis has guided the choice to Polyvinyl Chloride (PVC) and Polyamide (PA6). The strain gauges made of these materials were glued to a specimen of aluminum alloy placed under cyclic fatigue. During testing the influence of load, testing frequency and adhesives used for bonding strain gauges were verified. The results obtained showed how the use of a PVC strain gauge solves some of the problems that had come with metal strain gauges.
MERLETTI, LUIGI
FANTONI, G.
ING IV - Facolta' di Ingegneria Industriale
21-lug-2010
2009/2010
L'estensimetria infrarossa vuole proporsi come valida alternativa a quella resistiva grazie alla semplicità che caratterizza la messa in opera degli estensimetri infrarossi rispetto a quelli resistivi. L'estensimetria infrarossa sfrutta l'effetto termoelastico per la rilevazione delle deformazioni strutturali. In questo lavoro di tesi la scelta del materiale con cui realizzare gli estensimetri si è rivolta alla plastica, così da eliminare le problematiche dovute all'eccessiva rigidezza che caratterizza gli estensimetri infrarossi realizzati in metallo. Un'analisi preliminare ha orientato la scelta verso il Polivinilcloruro (PVC) e il Poliammide6 (PA6). Gli estensimetri realizzati con questi materiali sono stati incollati ad un provino in lega di alluminio posto in prova a fatica ciclica. Durante i test si è voluto verificare l'influenza del carico, delle frequenze di prova e degli adesivi utilizzati per l'incollaggio degli estensimetri. I risultati ottenuti hanno dimostrato come l'utilizzo di un estensimetro in PVC risolva alcune delle problematiche che si erano manifestate con gli estensimetri metallici.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2010_07_Gazzola.pdf

accessibile in internet per tutti

Descrizione: Testo della tesi
Dimensione 9.08 MB
Formato Adobe PDF
9.08 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/2401