Plasma wakefield acceleration is a promising concept for achieving accelerating gradients much higher than those available in conventional radiofrequency accelerators. In the AWAKE experiment at CERN, plasma wakefields are driven by high-energy proton bunches from the Super Proton Synchrotron (SPS), with the long-term goal of accelerating externally injected electron bunches, referred to as witness bunches, to very high energies in a single plasma. In the upcoming experimental campaign, Run 2c, preserving the quality of the electron bunch during acceleration is the main objective. To achieve that, the witness beam must be matched to the transverse focusing force of the plasma wake, a condition known as beam–plasma matching, in order to avoid transverse envelope oscillations, charge loss, and possible emittance degradation. This thesis presents a numerical study of electron-bunch–plasma matching for AWAKE Run 2c. The work focuses on a possible electron-only experimental configuration, without protons from the SPS. This choice is motivated by the fact that the high-density electron bunch can independently generate an ion cavity, corresponding to a strongly nonlinear regime known as the blowout regime. The aim of this work is to determine whether this type of experiment can be used to identify when electron bunches enter the plasma under matched conditions, before performing more complex experiments that include the full proton-driver–electron-witness system. Three-dimensional quasi-static particle-in-cell simulations were performed with HiPACE++ in order to investigate how deviations from the matched condition affect the beam evolution and the quantities measurable after propagation through the plasma. The input parameters that were varied are the initial transverse beam size σr,0, while keeping the waist position fixed at the plasma entrance, and the waist position zwaist, while keeping the beam size at the waist equal to the matched value. These scans were used to identify post-plasma observables that may serve as experimental signatures of electron-bunch–plasma matching. The simulation results show that the charge remaining after propagation through the 10 m-long plasma column, Qexit, is the most promising matching diagnostic. In both scans, the matched configuration corresponds to a maximum of the remaining charge. The simulations also suggest that some features of the energy spectrum of the electron bunches after propagation through the plasma column may provide matching-related signatures. However, their actual experimental usefulness still needs to be verified. In particular, it is necessary to assess whether the beam energy spectrum is significantly modified during propagation in vacuum between the plasma exit and the spectrometer. It is also necessary to determine whether the differences between the spectra associated with matched and unmatched cases are large enough to be resolved by the available spectrometric diagnostics.

L’accelerazione mediante plasma wakefield rappresenta una tecnica promettente per raggiungere gradienti di accelerazione molto più elevati rispetto a quelli disponibili negli acceleratori convenzionali a radiofrequenza. Nell’esperimento AWAKE al CERN, i wakefield sono generati da bunch di protoni (driver) ad alta energia provenienti dal Super Proton Synchrotron (SPS), con l’obiettivo a lungo termine di accelerare bunch di elettroni (witness) iniettati esternamente lungo stadi di plasma di scala metrica ad altissime energie. Nella prossima campagna sperimentale, Run 2c, preservare la qualità del bunch elettronico durante la sua accelerazione rappresenta uno degli obiettivi principali. Ciò richiede di adattare tale bunch alla forza trasversa di focalizzazione del wake di plasma, condizione nota come matching. Il matching beam-plasma permette di evitare oscillazioni del raggio trasverso del fascio, perdita di carica e possibile degradazione dell’emittanza. Questa tesi presenta uno studio numerico del matching tra bunch di elettroni e il plasma per AWAKE Run 2c. Il lavoro si concentra su una possibile configurazione sperimentale con solo fascio elettronico, senza protoni dal SPS, motivata dal fatto che il bunch di elettroni, essendo ad alta densità, può generare autonomamente una cavità ionica, ossia un regime altamente non lineare noto come regime di blowout. Lo scopo di questo lavoro è valutare se tale configurazione sperimentale permetta di identificare le condizioni in cui un fascio elettronico viene iniettato nel plasma in regime di matching, prima di effettuare più complicati esperimenti che includono l’intero sistema formato dal driver protonico e dal witness elettronico. Sono state eseguite simulazioni tramite il codice tridimensionale particle-in-cell quasi-statico HiPACE++, al fine di investigare come deviazioni dalla condizione di matching influenzino l’evoluzione del fascio e le grandezze misurabili dopo la propagazione nel plasma. Sono state considerate due scansioni indipendenti. Nella prima, la dimensione trasversa iniziale del fascio σr,0 è stata variata mantenendo la posizione del waist fissata all’ingresso del plasma. Nella seconda, la posizione del waist zwaist è stata variata mantenendo la dimensione del fascio al waist uguale al valore di matching. Queste scansioni sono state utilizzate per identificare osservabili post-plasma che possano servire come segnali sperimentali del matching fascio elettronico–plasma. I risultati delle simulazioni mostrano che la carica rimanente dopo la propagazione attraverso la colonna di plasma lunga 10 m, Qexit, è la diagnostica di matching più promettente. In entrambe le scansioni, la configurazione di matching corrisponde a un massimo della carica rimanente. Le simulazioni suggeriscono che anche alcune caratteristiche dello spettro energetico dei fasci elettronici dopo la propagazione nella colonna di plasma potrebbero costituire segnali di matching. Tuttavia, la sua effettiva utilità sperimentale deve ancora essere verificata. In particolare, occorre valutare se lo spettro energetico del fascio venga modificato in modo significativo durante la propagazione nel vuoto tra l’uscita della colonna di plasma e lo spettrometro. Inoltre, è necessario stabilire se le differenze tra gli spettri associati ai casi matched e unmatched siano sufficientemente grandi da poter essere risolte dalle diagnostiche spettrometriche disponibili.

Numerical study of electron beam-plasma matching for Awake Run 2c

MAROTTA, RAFFAELE
2025/2026

Abstract

Plasma wakefield acceleration is a promising concept for achieving accelerating gradients much higher than those available in conventional radiofrequency accelerators. In the AWAKE experiment at CERN, plasma wakefields are driven by high-energy proton bunches from the Super Proton Synchrotron (SPS), with the long-term goal of accelerating externally injected electron bunches, referred to as witness bunches, to very high energies in a single plasma. In the upcoming experimental campaign, Run 2c, preserving the quality of the electron bunch during acceleration is the main objective. To achieve that, the witness beam must be matched to the transverse focusing force of the plasma wake, a condition known as beam–plasma matching, in order to avoid transverse envelope oscillations, charge loss, and possible emittance degradation. This thesis presents a numerical study of electron-bunch–plasma matching for AWAKE Run 2c. The work focuses on a possible electron-only experimental configuration, without protons from the SPS. This choice is motivated by the fact that the high-density electron bunch can independently generate an ion cavity, corresponding to a strongly nonlinear regime known as the blowout regime. The aim of this work is to determine whether this type of experiment can be used to identify when electron bunches enter the plasma under matched conditions, before performing more complex experiments that include the full proton-driver–electron-witness system. Three-dimensional quasi-static particle-in-cell simulations were performed with HiPACE++ in order to investigate how deviations from the matched condition affect the beam evolution and the quantities measurable after propagation through the plasma. The input parameters that were varied are the initial transverse beam size σr,0, while keeping the waist position fixed at the plasma entrance, and the waist position zwaist, while keeping the beam size at the waist equal to the matched value. These scans were used to identify post-plasma observables that may serve as experimental signatures of electron-bunch–plasma matching. The simulation results show that the charge remaining after propagation through the 10 m-long plasma column, Qexit, is the most promising matching diagnostic. In both scans, the matched configuration corresponds to a maximum of the remaining charge. The simulations also suggest that some features of the energy spectrum of the electron bunches after propagation through the plasma column may provide matching-related signatures. However, their actual experimental usefulness still needs to be verified. In particular, it is necessary to assess whether the beam energy spectrum is significantly modified during propagation in vacuum between the plasma exit and the spectrometer. It is also necessary to determine whether the differences between the spectra associated with matched and unmatched cases are large enough to be resolved by the available spectrometric diagnostics.
ING - Scuola di Ingegneria Industriale e dell'Informazione
22-lug-2026
2025/2026
L’accelerazione mediante plasma wakefield rappresenta una tecnica promettente per raggiungere gradienti di accelerazione molto più elevati rispetto a quelli disponibili negli acceleratori convenzionali a radiofrequenza. Nell’esperimento AWAKE al CERN, i wakefield sono generati da bunch di protoni (driver) ad alta energia provenienti dal Super Proton Synchrotron (SPS), con l’obiettivo a lungo termine di accelerare bunch di elettroni (witness) iniettati esternamente lungo stadi di plasma di scala metrica ad altissime energie. Nella prossima campagna sperimentale, Run 2c, preservare la qualità del bunch elettronico durante la sua accelerazione rappresenta uno degli obiettivi principali. Ciò richiede di adattare tale bunch alla forza trasversa di focalizzazione del wake di plasma, condizione nota come matching. Il matching beam-plasma permette di evitare oscillazioni del raggio trasverso del fascio, perdita di carica e possibile degradazione dell’emittanza. Questa tesi presenta uno studio numerico del matching tra bunch di elettroni e il plasma per AWAKE Run 2c. Il lavoro si concentra su una possibile configurazione sperimentale con solo fascio elettronico, senza protoni dal SPS, motivata dal fatto che il bunch di elettroni, essendo ad alta densità, può generare autonomamente una cavità ionica, ossia un regime altamente non lineare noto come regime di blowout. Lo scopo di questo lavoro è valutare se tale configurazione sperimentale permetta di identificare le condizioni in cui un fascio elettronico viene iniettato nel plasma in regime di matching, prima di effettuare più complicati esperimenti che includono l’intero sistema formato dal driver protonico e dal witness elettronico. Sono state eseguite simulazioni tramite il codice tridimensionale particle-in-cell quasi-statico HiPACE++, al fine di investigare come deviazioni dalla condizione di matching influenzino l’evoluzione del fascio e le grandezze misurabili dopo la propagazione nel plasma. Sono state considerate due scansioni indipendenti. Nella prima, la dimensione trasversa iniziale del fascio σr,0 è stata variata mantenendo la posizione del waist fissata all’ingresso del plasma. Nella seconda, la posizione del waist zwaist è stata variata mantenendo la dimensione del fascio al waist uguale al valore di matching. Queste scansioni sono state utilizzate per identificare osservabili post-plasma che possano servire come segnali sperimentali del matching fascio elettronico–plasma. I risultati delle simulazioni mostrano che la carica rimanente dopo la propagazione attraverso la colonna di plasma lunga 10 m, Qexit, è la diagnostica di matching più promettente. In entrambe le scansioni, la configurazione di matching corrisponde a un massimo della carica rimanente. Le simulazioni suggeriscono che anche alcune caratteristiche dello spettro energetico dei fasci elettronici dopo la propagazione nella colonna di plasma potrebbero costituire segnali di matching. Tuttavia, la sua effettiva utilità sperimentale deve ancora essere verificata. In particolare, occorre valutare se lo spettro energetico del fascio venga modificato in modo significativo durante la propagazione nel vuoto tra l’uscita della colonna di plasma e lo spettrometro. Inoltre, è necessario stabilire se le differenze tra gli spettri associati ai casi matched e unmatched siano sufficientemente grandi da poter essere risolte dalle diagnostiche spettrometriche disponibili.
File allegati
File Dimensione Formato  
Executive_Summary__Marotta.pdf

accessibile in internet per tutti

Descrizione: Executive Summary
Dimensione 2.73 MB
Formato Adobe PDF
2.73 MB Adobe PDF Visualizza/Apri
Msc_thesis_awake_polimi_marotta_FIN.pdf

accessibile in internet per tutti

Descrizione: Tesi
Dimensione 8.13 MB
Formato Adobe PDF
8.13 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/261244