High-rise buildings can experience large across-wind response due to the vortex excitation generated by the detached flow around the bluff-body. The capability to predict this motion is fundamental for design purpose and occupancy comfort evaluation. Once the wind loads are known, for instance by wind tunnel tests on rigid models, the tower response can be numerically evaluated. Nevertheless, when the tower, during the oscillations, experiences motion-induced forces the predicted response can be significantly different from the real one if aeroelastic effects are not evaluated. This study investigates this problem by the wind tunnel tests on rigid and aeroelastic model of rectangular section prism, having he wind force simultaneously measured together the tower displacement. After the comparison between the computed responses, evaluated using the wind pressure on the non-moving and moving model, the tower response was predicted by numerical model including aeroelastic parameters evaluated from experimental test.

Gli edifici ad elevato sviluppo verticale possono sperimentare grandi risposte in direzione perpendicolare al vento a causa dell’eccitazione da vortici generata dal distacco del flusso attorno ai corpi tozzi. La capacità di predire questo moto è di fondamentale importanza nella progettazione e nella valutazione del comfort. Una volta che i carichi eolici sono noti, per esempio dai test in galleria del vento su modelli rigidi, la risposta della torre può essere valutata numericamente. Tuttavia, quando la torre, durante le oscillazioni, sperimenta le forze dipendenti dal moto, la risposta predetta può essere significativamente differente da quella reale se gli effetti aeroelastici non sono stati valutati. Questo lavoro investiga questo problema attraverso test condotti in galleria del vento su un modello rigido ed aeroelastico di un prisma a sezione rettangolare, avendo misurato contemporaneamente le forze eoliche e lo spostamento della torre. Dopo aver confrontato i risultati ottenuti, valutate usando le pressioni eoliche sui due modelli, è stata predetta la risposta della torre attraverso un modello numerico che includesse i parametri aeroelastici valutati attraverso le prove sperimentali.

Sulla risposta dinamica ed aeroelastica all'azione eolica di una torre a sezione rettangolare

AMATO, ROBERTO
2009/2010

Abstract

High-rise buildings can experience large across-wind response due to the vortex excitation generated by the detached flow around the bluff-body. The capability to predict this motion is fundamental for design purpose and occupancy comfort evaluation. Once the wind loads are known, for instance by wind tunnel tests on rigid models, the tower response can be numerically evaluated. Nevertheless, when the tower, during the oscillations, experiences motion-induced forces the predicted response can be significantly different from the real one if aeroelastic effects are not evaluated. This study investigates this problem by the wind tunnel tests on rigid and aeroelastic model of rectangular section prism, having he wind force simultaneously measured together the tower displacement. After the comparison between the computed responses, evaluated using the wind pressure on the non-moving and moving model, the tower response was predicted by numerical model including aeroelastic parameters evaluated from experimental test.
GIAPPINO, STEFANO
TOMASINI, GISELLA
ING IV - Facolta' di Ingegneria Industriale
21-lug-2010
2009/2010
Gli edifici ad elevato sviluppo verticale possono sperimentare grandi risposte in direzione perpendicolare al vento a causa dell’eccitazione da vortici generata dal distacco del flusso attorno ai corpi tozzi. La capacità di predire questo moto è di fondamentale importanza nella progettazione e nella valutazione del comfort. Una volta che i carichi eolici sono noti, per esempio dai test in galleria del vento su modelli rigidi, la risposta della torre può essere valutata numericamente. Tuttavia, quando la torre, durante le oscillazioni, sperimenta le forze dipendenti dal moto, la risposta predetta può essere significativamente differente da quella reale se gli effetti aeroelastici non sono stati valutati. Questo lavoro investiga questo problema attraverso test condotti in galleria del vento su un modello rigido ed aeroelastico di un prisma a sezione rettangolare, avendo misurato contemporaneamente le forze eoliche e lo spostamento della torre. Dopo aver confrontato i risultati ottenuti, valutate usando le pressioni eoliche sui due modelli, è stata predetta la risposta della torre attraverso un modello numerico che includesse i parametri aeroelastici valutati attraverso le prove sperimentali.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
Sulla risposta dinamica ed aeroelastica all'azione eolica di una torre a sezione rettangolare.pdf

accessibile in internet per tutti

Descrizione: Testo della tesi
Dimensione 2.61 MB
Formato Adobe PDF
2.61 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/2684