The current state-of-the-art for the design of buildings’ façade relies mainly on the prescription given by national codes. These prescriptions, even if valid for ordinary building, are often not detailed enough for the design of building out of the ordinary. For these building designers that want to have a deeper knowledge of the wind pressures on the building and on the building elements can only rely on the wind tunnel tests. CFD techniques are nowadays not sufficiently reliable for the evaluation of localised peak pressures. CFD however offers several benefits, such as an easier analysis of the flow without the need of acquisition instrumentation or an easier model geometry manipulation. The definition of a reliable stand- ardised method for the calculation of design loads using CFD would allow to reduce the building façades oversize; reducing the cladding cost.

Lo stato dell’arte attuale per la progettazione delle facciate degli edifici si affida principalmente alle prescrizioni fornite dalle normative nazionali. Queste normative, sebbene valide per edifici ordinari, sono spesso non sufficientemente dettagliate per il progetto di edifici di natura straordinaria. Per questi ultimi, il progettista che desiderasse una conoscenza più approfondita delle pressioni generate dal vento sui singoli elementi può fare affidamento solamente alle prove in galleria del vento. La tecniche CFD, al giorno d’oggi, non sono sufficientemente affidabili per la valutazione dei picchi di pressione localizzati. La CFD però offre diversi vantaggi, come un’analisi più facile del flusso senza la necessità di strumenti di acquisizione o una più facile manipolazione della geometria del modello. La definizione di un metodo affidabile e standardizzato per il calcolo dei carichi eolici con la CFD permetterebbe di ridurre il sovradimensionamento delle facciate; riducendo i costi dei rivestimenti degli edifici.

Numerical and experimental analysis of peak pressure loads on rectangular building

AMERIO, LUCA
2013/2014

Abstract

The current state-of-the-art for the design of buildings’ façade relies mainly on the prescription given by national codes. These prescriptions, even if valid for ordinary building, are often not detailed enough for the design of building out of the ordinary. For these building designers that want to have a deeper knowledge of the wind pressures on the building and on the building elements can only rely on the wind tunnel tests. CFD techniques are nowadays not sufficiently reliable for the evaluation of localised peak pressures. CFD however offers several benefits, such as an easier analysis of the flow without the need of acquisition instrumentation or an easier model geometry manipulation. The definition of a reliable stand- ardised method for the calculation of design loads using CFD would allow to reduce the building façades oversize; reducing the cladding cost.
ZASSO, ALBERTO
TAMURA, TETSUO
SCHITO, PAOLO
GIAPPINO, STEFANO
VAZZANA, GIUSEPPE
ING I - Scuola di Ingegneria Civile, Ambientale e Territoriale
25-lug-2014
2013/2014
Lo stato dell’arte attuale per la progettazione delle facciate degli edifici si affida principalmente alle prescrizioni fornite dalle normative nazionali. Queste normative, sebbene valide per edifici ordinari, sono spesso non sufficientemente dettagliate per il progetto di edifici di natura straordinaria. Per questi ultimi, il progettista che desiderasse una conoscenza più approfondita delle pressioni generate dal vento sui singoli elementi può fare affidamento solamente alle prove in galleria del vento. La tecniche CFD, al giorno d’oggi, non sono sufficientemente affidabili per la valutazione dei picchi di pressione localizzati. La CFD però offre diversi vantaggi, come un’analisi più facile del flusso senza la necessità di strumenti di acquisizione o una più facile manipolazione della geometria del modello. La definizione di un metodo affidabile e standardizzato per il calcolo dei carichi eolici con la CFD permetterebbe di ridurre il sovradimensionamento delle facciate; riducendo i costi dei rivestimenti degli edifici.
Tesi di laurea Magistrale
File allegati
File Dimensione Formato  
2014_7_Amerio.pdf

accessibile in internet per tutti

Descrizione: Testo della tesi
Dimensione 50.42 MB
Formato Adobe PDF
50.42 MB Adobe PDF Visualizza/Apri

I documenti in POLITesi sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10589/94331